Mobile Rope Measurement MSM 12
Henning GmbH
Page 13
2.0 / 3.2009
7.4.2.2
Select sensor type
For the WeightWatcher mobile system three different sensor types for different rope
diameters are available:
- LSM1
diameter 6mm – 16mm
- LSM2
diameter 4mm – 10mm
- LSM-XL
diameter 16mm – 24mm
In order to enable the load meter to work correctly with the different sensors, the user
must select the sensor used.
In this configuration menu you may choose among the use of LSM1 or LSM2 sensors
or the use of LSM XL sensors.
The selected sensor type is permanently stored and also after a restart of the load
meter it is selected by default.
Figure 7: Selection of the sensor type
7.4.2.3
Set suspension ratio
Under this menu item you can enter the suspension ratio of the elevator at which you
want to carry out measurements. The ratio is displayed on the main display; how-
ever, it is not permanently stored in the load meter. After a restart the load meter
starts automatically with a suspension of 1 : 1.
By means of the suspension ratio entered the displayed total weight is calculated.
The suspension ratio has no influence on the individual rope loads.