background image

Read entire manual before assembling, 

installing, operating, or servicing this 

equipment.

NOTICE

ii • 

Important: Always read and follow instructions.

READ ALL INSTRUCTIONS

1.   Do not stare directly into light source of the 

unit.

2.   

Read and understand this manual before 

operating. Abuse and misuse will shorten the 

functional life.

3.   Do not operate equipment with a damaged 

cord or if the equipment has been dropped 

or damaged – until it has been examined and 

repaired by a qualified serviceman.

4.   Do not let cord hang over edge of table, bench, 

or counter or sharp metal object edges.

5.   If an extension cord is necessary, a cord with a 

current rating equal to or more than that of the 

equipment should be used. Cords rated for less 

current than the equipment may overheat. Care 

should be taken to arrange the cord so that it 

will not be tripped over or pulled.

6.   Keep guards and safety features in place and in 

working order.

7.   

Keep work area clean and well lighted. 

Cluttereand/or dark areas invite accidents.

8.   

Avoid dangerous environments. Do not use 

power tools or electrical equipment in damp or 

wet locations, or expose them to rain.

9.  

Use only manufacturer’s recommended 

accessories. Improper accessories may result 

in personal injury or property damage.

10.   Repair or replace any part that is damaged or 

worn. Do not operate damaged equipment 

until it has been examined and serviced by an 

authorized service technician only. This unit 

contain no user serviceable parts.

11.   

Do not allow untrained persons to operate 

machinery.

12.  

To reduce the risk of fire, do not operate 

equipment in the vicinity of open containers or 

flammable liquids (gasoline).

13.  

Use equipment only as described in this 

manual. Do not modify the unit or remove 

protective covers or housings.

14. 

 

Use only manufacturer’s recommended 

attachments and accessories. 

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Содержание COATS Tread Scanner

Страница 1: ...achine for ease of reference by supervisors and operators Tread Scanner 1601 J P Hennessy Drive La Vergne TN USA 37086 615 641 7533 800 688 6359 www coatsgarage com Manual Part No 85611869 01 HENNESSY...

Страница 2: ...or pulled 6 Keep guards and safety features in place and in working order 7 Keep work area clean and well lighted Cluttereand or dark areas invite accidents 8 Avoid dangerous environments Do not use...

Страница 3: ...iv Symbols Used iv Installation Instructions 1 Information on Pre installation Location 1 Assembly Case for Floor Level Installation 2 Evenness of The Measuring Unit 2 Network Environment 2 Special Ac...

Страница 4: ...toes and oil resistant soles should be used by tire service personnel to help prevent injury in typical shop activities Eye protection is essential during tire service activity Safety glasses with sid...

Страница 5: ...ave low bearing pressures Special care is required when bolting with asphalt anchors optional accessories Troughs or sleepers e g gullet that influence the speed or vibration behavior of the vehicle a...

Страница 6: ...sses for Smart TV Designation Standard IP Addresses Factory setting of the modules 192 168 10 1 Master static 192 168 10 10 Satellite static 192 168 10 20 Camera 192 168 10 30 Customer PC 192 168 10 1...

Страница 7: ...net Switch and access point max distance to Tread Scanner 26 1 4 feet 8 meter 3 Straight drive down path min length 10 feet 3 meter 4 Master measuring unit 3 1 2 to 8 feet 1 06 x 2 445 meter 5 Satelli...

Страница 8: ...modules connected directly via network This installation is not suited to be set up on a working pit Fig 5 Connecting the master and satellite to the network 1 Computer optional Digital Signage 2 Elec...

Страница 9: ...dules individually to external switch No Camera possible Fig 6 Connecting both modules individually to external switch 1 Computer optional Digital Signage 2 External switch 3 Electrical cabinet 4 Dire...

Страница 10: ...m 4 Max outer track width 80 7 8 inches 2 055 m 5 Min access route Access route recommended 118 inches 3 000 m 157 1 2 inches 4 000 m 6 Distance between the ramps 29 3 8 inches 0 745 m 7 Min distance...

Страница 11: ...Important Always read and follow instructions 7 Foundation Layout i i Only for Tread Scanner floor level i i All dimensions in cm...

Страница 12: ...oncrete quality min C20 25 DIN EN 19992 1 1 5 Crossing direction As reference 6 Hazard zone Hazard area to mark the tread depth measuring device acc to DIN 4844 T1 7 Water discharge pipe 9 Cable lengt...

Страница 13: ...Important Always read and follow instructions 9 Floor Levelness and Central Unit...

Страница 14: ...to RJ45 33 feet 10 m 85611858 Set up B installation on working pit 1x Electrical cabinet with 2 power supply units PartNumber 2x Power supply cable Neutrik to M12 33 feet 10 m 85611860 2x Data cable M...

Страница 15: ...of delivery do not fit the customer must provide 2 country specific IEC cables Dimensions checked see Size Floor levelness checked see Floor Levelness and Central Unit Floor load bearing capacity che...

Страница 16: ...85611869 01 09 20 Copyright 2020 Hennessy Industries LLC...

Отзывы: