background image

 

 

2331226 EQ CL36 LED Cure Chamber 

 

 

Operating Manual 

 

 

 
 
 

 

Содержание 2331226

Страница 1: ...1 2331226 EQ CL36 LED Cure Chamber Operating Manual ...

Страница 2: ... 3 Technical Data 6 4 Installation 6 4 1 Environmental and Operating Conditions 6 4 2 Connecting the Unit 6 5 Setup 7 5 1 Overview 7 5 2 Electrical Connection 8 5 3 Turn on Chamber 8 6 Operation 9 6 1 Setup Parameter 9 6 2 Run the Chamber 11 6 3 Pause 12 7 Troubleshooting 13 8 Care and Maintenance 13 9 Accessories and Spare Parts 14 10 Diagrams 15 11 Warranty 17 12 Declaration of Conformity 19 ...

Страница 3: ...it read these instructions completely If the instructions are not observed the manufacturer can assume no responsibility Do not expose the connecting cable to heat oil or sharp edges Do not bypass interlock any time Make sure the Unit stands stable and secure Use only original equipment replacement parts Always wear UV glasses when operating the chamber Always disconnect the power supply before se...

Страница 4: ... Rotary table with 2kg payload 1 5 4 Touch screen user interface with color display 1 5 5 Accepts part sizes up to 300mm x 300mm x 255mm 1 5 6 Independently adjustable digital timers for top and side LED floods 1 5 7 Uniform intensity throughout chamber volume 1 5 8 Universal power supply 1 6 Usage The Loctite CL36 LED Curing Chamber is an all new state of the art UV curing station that s been spe...

Страница 5: ...a rotary table the chamber can cure all sides of parts in one time Variable intensity capability allows adjustment of the light intensity based on the application and resin type resulting in optimal cured performance of the resin Adjustable from 10 100 in 1 increments Large 200 x 200mm top and side LED flood lights allow for a wide range of part sizes LED floods provide instant on off and do no em...

Страница 6: ...sing the equipment for the first time check it carefully for signs of external damage If any shipping damage is found DO NOT USE THE EQUIPMENT return it to your supplier immediately 4 1 Environmental and Operating Conditions The equipment should be installed in a dry well ventilated and dust free place To ensure proper ventilation install the unit at a distance of at least 100 150 mm from a wall o...

Страница 7: ...7 5 Setup 5 1 Overview ...

Страница 8: ... Switch 9 Side LED Flood 10 Top LED Flood 11 Door Switch Do not press door switch any time 12 Rotary Table 5 2 Electrical Connection Plug the AC power cord into N0 7 Power Inlet which located in rear side of chamber 5 3 Turn on Chamber Switch on the power switch No 8 Make sure EMO button No 1 be released Turn on No 2 switch ...

Страница 9: ...on 6 1 Setup Parameter As below picture press Setting Locked button on panel will enter setup page Click each area to setup each parameter detail as below 1 Setup LED power for top flood The adjust range is 10 100 ...

Страница 10: ...ill be 00 03 means curing time is 3 seconds when you key in 30 the curing time will be 00 30 means curing time is 30 seconds When you key in 130 the curing time will be 01 30 means curing time is 1 minutes and 30 seconds When you key in 1130 the curing time will be 11 30 means curing time is 11 minutes and 30 seconds When you set time to 0 the flood will not work during curing 3 Setup LED power fo...

Страница 11: ... You will define if the table will rotate during curing or not 6 Click this button to save and exit 6 2 Run the Chamber As below picture click below button START STOP to run the chamber You also can click the START STOP button to stop the chamber during curing ...

Страница 12: ...ator will show as you will need to open the door or click two times to recover the statue 6 3 Pause As below picture click the PAUSE button to pause during curing And click Continue to back to cure Timer will continue when back from pause ...

Страница 13: ...e until it pops out Main switch is not turned on Turn on the main switch which locate on front top panel Fuse break Check the fuse in power inlet Cannot start curing indicate Door Open Door is opened Close door Door switch is defective Check door switch Contact Henkel service Cannot start curing indicate Complete Press START button twice Or open door and close it Indicator UV ALARM LED flood overh...

Страница 14: ...nd Spare Parts OPTIONAL ACCESSORIES SPARE PARTS UV V Light Radiometer Dosimeter 265282 EQ PR11 DLP PRINTER 2416987 EQ PR10 DLP PRINTER 2312297 EQ CL36 CABLE 2423147 CL36 LED CONTROLLER 2423148 CL36 LED FLOOD HEAD 2423149 ...

Страница 15: ...15 10 Diagrams ...

Страница 16: ...16 ...

Страница 17: ...s not apply to perishable items No such claim shall be allowed in respect of products which have been neglected or improperly stored transported handled installed connected operated used or maintained In the event of unauthorized modification of the Products including where products parts or attachments for use in connection with the Products are available from Henkel the use of products parts or ...

Страница 18: ...OING TO THE FULLEST EXTENT POSSIBLE UNDER APPLICABLE LAWS HENKEL EXPRESSLY DISCLAIMS ANY LIABILITY WHATSOEVER FOR ANY DAMAGES INCURRED DIRECTLY OR INDIRECTLY IN CONNECTION WITH THE SALE OR USE OF OR OTHERWISE IN CONNECTION WITH THE PRODUCTS INCLUDING WITHOUT LIMITATION LOSS OF PROFITS AND SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES WHETHER CAUSED BY NEGLIGENCE FROM HENKEL OR OTHERWISE ...

Страница 19: ...19 12 Declaration of Conformity ...

Страница 20: ...20 ...

Страница 21: ...149598 Henkel China Company Ltd No 928 Zhang Heng Road Zhangjiang Hi Tech Park Pudong Shanghai China 201203 Henkel Loctite Korea 8F Mapo Tower 418 Mapo dong Mapo gu Seoul 121 734 KOREA Henkel Japan Ltd 27 7 Shin Isogo cho Isogo ku Yokohama 235 0017 JAPAN Henkel AG Co KGaA Standort München Gutenbergstraße 3 85748 Garching b München Deutchland www equipment loctite com and designate trademarks of He...

Отзывы: