![Hengstler AX70 Series Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/hengstler/ax70-series/ax70-series_installation-instructions-manual_2123910010.webp)
Item number: 2-539-114, version: 3 121113TK
10 of 12
Shaft diameter
10mm
Shaft load
radial 100N, axial 40N
Max. speed
1000 min-1 (Ex d IIC T6) / 10 000 min-1 (Ex d IIC T4); or see classifi-
cation page 9
Torque
1Ncm
Moment of inertia
14gcm
2
approx.
Protection class (EN 60529/ A1:2000-02)
housing IP67, bearing IP67
1)
ambient temperature
-40°C … +40°C (Ex d IIC T6) / -40°C … +60°C (Ex d IIC T4); or see
classification page 9
Storage temperature
-25°C ... +85°C
Vibration performance (IEC 68-2-6)
100m/s
2
(10 ... 60Hz 1.5mm; 60 ... 2000Hz 100m/s
2
)
Shock resistance (IEC 68-2-27)
1000m/s
2
(6ms)
Connection
cable axial or radial for fixed installation
Size
ø70mm
Mounting
clamping flange, bores 3xM6
Weight
AX70 1400g approx. ; AX71 4800g approx.
1)
no standing water allowed at the shaft entrance or cable entrance or at the ball bearing.
Mechanical data
Interface
serial (SSI), BiSS
Resolution
1024 steps (10 Bit) Singleturn
4096 steps (12 Bit) Singleturn
8192 steps (13 Bit) Singleturn
16384 steps (14 Bit) Singleturn
4096 steps / 4096 turns (24 Bit) Multiturn
8192 steps / 4096 turns (25 Bit) Multiturn
16384 steps / 4096 turns (26 Bit) Multiturn
Linearity
±½ LSB
Type of code
Gray or Binary
Supply voltage
10...30V DC (with pole protection)
Power consumption
max. 200mA
External fuse
T0.25 A
Baud rate
70KB...1.5MB
2)
Inputs
Direction
Output driver
RS485
Alarm output
Alarm bit
Parity bit
on request
Max. cable length
400m
2)
2)
The maximum data transmission rate depends on the cable length. Please use screened cable with
twisted cable pairs for clock / clock and data / data.
Electrical data (absolute)