20 of 22
Item number: 2-569-013, Version: 3 200116TK
EN
6. Admissible cable lengths
Max. cable length
max. 400m
Cable length
Baudrate
<25m
< 800 kHz
<50m
< 400 kHz
<100m
< 300 kHz
<200m
< 200 kHz
<400m
< 100 kHz
7. Connection diagram
Terminal block
Signal
1
U in 10...30V DC
2
0V (GND Power supply)
3
Clock
4
Clock
5
Data
6
Data
7
Direction
8
Preset (set to zero)
9
Not connected
10
PE
Screen
cable screen connected to housing
Terminal screw
for additional connection of an earth
conductor