31
T51002 E
InstallatIon, servIce and troubleshootIng Procedures
H
I
E
E
J
G
F
B
C
A
C
B
D
Item
Description
Supplied with TIREMAAX
®
A. Air line
1
/
4
inch OD nylon air brake tubing
B. Axle connector
90 degree elbow,
1
/
8
inch NPT male to
1
/
4
inch NTA (Nylon Tubing Adapter)
C. Axle hose fitting
1
/
8
inch NPT female
D. Axle vent fitting
High flow axle vent (includes check valve)
Provided by installer
E. Air line
3
/
8
inch OD nylon air brake tubing
F. Controller IN fitting
1
/
4
inch NPT male to
3
/
8
inch NTA
G. Controller OUT fitting
Run tee;
1
/
4
inch NPT male,
1
/
4
inch NTA,
1
/
4
inch NTA (three total) (gauge is optional)
H. Pressure protection valve (PPV)
Required; 70 PSI minimum closing pressure; existing suspension valve can be used
I. PPV OUT fitting
Run tee;
1
/
4
inch NPT male,
3
/
8
inch NTA,
3
/
8
inch NTA
J. Emergency supply IN fitting
1
/
4
inch NPT male to
3
/
8
inch NTA
1
May be provided with Height Control Valve (HCV) or Dock Stabilizing Technology™ (DST
®
) kit.
Figure 38:
Typical TIREMAAX
®
PRO
plumbing schematic - single axle with
3
/
8
and
1
/
4
inch lines.
Trailer air tank
To height control valve
Emergency supply IN
(not included on CP)
NOTE:
To maintain adequate
airflow, all air lines coming
into and going out of the
controller assembly must be
3
/
8
inch. All junctions of two
or more
1
/
4
inch lines must
be supplied by
3
/
8
inch line.
Front