ASSEMBLING
The power must be turned off when replacing the fil
-
ters. Install the spark screen, pre-filter, and particulate
filter (gas filter if any) in filter cover.
Before installed, always make sure filter material is in
-
tact and dry with no tears or other damages. Install the
filter cover assembly to the blower unit by engaging
tabs on filter cover into bracket on blower unit and rota
-
te assembly to close. Push filter cover assembly down
until latch clicks into position securing filter cover as
-
sembly. Inspect both sides of cover to see that the filter
cover is properly installed. To replace filter, push latch
into release filter cover and replace filter as shown in
the here below picture.
When to replace the filter: If the filter gets blocked by
contaminants, all the three points of warning lights will
flash, accompanied with vibrate and bleeping sound.
Please immediately exit contaminated environment
and check the status.
PARTICULATE FILTER
WARNING
•
Never use the respirator without the spark screen,
pre-filter, and the HE particulate filter (HEPA) installed.
•
Always replace filter when damaged or blocked. Do
not try to wash, clean or reuse dirty ones.
•
Stored at a temperature between 14°F to 131°F
(-10°C to 55°C) in a clean environment without direct
light.
•
Remember not confuse the markings on a filter re
-
lating to any standard other than EN 12941 with the
classification of this device when used with this filter.
•
Please install the particle filter according to fig.14.
•
The time limit for the storage of new filters kept in
their original packaging is 5 years.
FIG. 13
FIG. 14
Filter
Cover
Latch
Spark
Screen
Pre-Filter
Particulate
Filter
FIG. 15
Filter
Cover
Latch
Spark
Screen
Pre-Filter
Particulate
Filter
Gas Filter
Marking
Code
Color
Protection Against
P (R SL)
21905157 White
P a r t i c u l a t e s
( R = r e p l a c e a b l e ,
SL=test against so
-
dium chloride and pa-
raffin oil)
A1B1E1K1 21905161
Brown
/ Grey /
Yellow
/ Green
Organic gases / Inor
-
ganic gases / Sulfur
dioxide, acidic gases /
Ammonia and organic
ammonia derivatives
BATTERY
WARNING
•
The battery should be charged in a place that is
electrically safe.
•
The charging time of different types of battery is dif
-
ferent. Actual charging time depends on the remaining
battery capacity.
•
Please check out the voltage of the charger
(220/230V).
•
Please separate the battery from the body before
charging.
•
Upon using-condition, the battery’s life may be
slightly different.
GAS FILTER
WARNING
•
This gas filter must be always used together with
FreFlow particle filter. The gas filter give additional pro
-
tection against certain gaseous environment. (See the
table below)
•
The particle filter and gas filter cannot be cleaned.
Stop using it immediately when smelling peculiar smell
and replace it until you are in a safe area.
•
Stored at a temperature between 14°F to 131°F (-10°C
to 55°C) in a clean environment without direct light.
•
Please install the particle filter and gas filter accor
-
ding to fig.15.
Filter
Filter efficiency: 99.97%
Alarms: Visible, audible and vibrate