Helvest FleX AB400 Скачать руководство пользователя страница 2

Helvest

 FleX Layout module AB400 - User Manual

WARNING:

 It is imperative to connect on the same AB400 module wires coming

from the same control unit, or the same booster. 
Connecting wires from different control units, or from different boosters, on the

same AB400 module may damage the control unit or the booster itself. This rule of

not connecting different digital sources together applies to any connection, even

without presence detection modules.

1.4 Mounting the board on the layout

ANext   to   the  AB400   module,   any   other

layout   module   can   be   installed:   e.g.   a

module for switches, for signals, a second

AB400   module   to   control   a   total   of   8

sections, etc. The complete board must be

mounted   so   that   it   does   NOT   touch   any

element   during   operation.   In   particular,   it

must not come into contact with any metal

material.

For temporary installations, it can be placed

on   a   non-flammable   insulating   surface

(plastic, glass, ceramic floor, etc.).

For   fixed   layouts,   it   is   recommended   to

mount it by screwing the HP100 onto a wooden surface with the screws and spacers

provided.   (figure).   This   must   be   done   before   inserting   the  AB400   module   (if

additional boards have already been inserted, they can be removed gently without

any problems).

2. BOARD OPERATION

2.1 Normal operation

Once all connections have been made, power the board. The green LED no. (5) (fig.

3) indicates that the power supply is correct.

The LEDs at positions no. (3) and (4), numbered 1 to 4, indicate the presence in the

4 sections of the board. If there are no locomotives or vehicles drawing current, the

lights must be switched off.

By placing a locomotive or a current-consuming vehicle (such as an illuminated car,

a car with tail lights, etc.) on the corresponding track section, the LED lights up.

Train presence data is sent to the network via the MVnet module. This data can be

processed by the computer or other boards as required.

2.2 Current flow and protection

Each section holds a maximum absorption of 2A, which is plenty for common model

railway applications.

In the event of a short circuit, the control unit itself or the power supply unit takes

care of disconnecting the current.

WARNING:

  Never   power   the   track   with   devices   that   are   not   short-circuit

protected! This rule is independent of the use of the AB400 module. 
In   any   system,   supplying   power   to   the   track   with   non-short-circuit-protected

devices can seriously damage your rolling stock and all connected equipment, as

well as present a fire risk.

2.3 Train detection

These sensors operate in both analogue and digital mode, and detect the presence of

the train in real time on the relevant section by noticing if a device is drawing current

on  that  section: a locomotive engine or its lights, or  simply the decoder if the

locomotive is digital. In digital operation, the decoder is detected even if no other

devices are active (so even a stationary locomotive with its lights off).

Passenger cars or freight wagons are detected if they are equipped with something

that draws current, such as tail lights, interior lighting, or a decoder. 

In the event of problems, such as some vehicles becoming uncoupled while running

or if the locomotive stops due to a lack of electrical contact, it is important that the

situation is also detected by the sensors.

For this reason, it is advisable to always protect both ends of the train, so that the tail

vehicle, if it is not illuminated or does not have its lights on, is also detected.

Fig. 4

Отзывы: