12
113
4 bytes
Relay control scenario 3
0
0, 10000000 to
43112359
114
4 bytes
Relay control scenario 4
0
0, 10000000 to
43112359
115
4 bytes
Relay control scenario 5
0
0, 10000000 to
43112359
116
4 bytes
Relay control scenario 6
0
0, 10000000 to
43112359
117
4 bytes
Relay control scenario 7
0
0, 10000000 to
43112359
118
4 bytes
Relay control scenario 8
0
0, 10000000 to
43112359
119
4 bytes
Relay control scenario 9
0
0, 10000000 to
43112359
120
4 bytes
Relay control scenario 10
0
0, 10000000 to
43112359
121-140
Reserved by the manufacturer
141
1 byte
Consumption meter consecutive reporting interval, minutes
10
1 … 120
142
1 byte
Consumption change report to send to controller
1
0, 1
143
1 byte
Sensors consecutive reporting interval, minutes
10
1 … 120
144
1 byte
Temperature difference to send to controller, value X 10
2
0, 1 … 100
145
1 byte
Humidity difference to send to controller, %
2
0, 1 … 25
146
1 byte
Light sensor values difference to send to controller, %
50
0, 10 … 99
147-170
Reserved by the manufacturer
171
1 byte
Touch control mode for associations with touch button 1
0
0, 1, 2
172
1 byte
Touch control mode for associations with touch button 2
0
0, 1, 2
173
1 byte
Touch control mode for associations with touch button 3
0
0, 1, 2
174
1 byte
Touch control mode for associations with touch button 4
0
0, 1, 2
Z-Wave Frequency
Parameter 01
– Frequency Region
The HE-TPS04 has Z-Wave 700 series chip inside which allows to use the device in different Z-Wave frequencies. If
there is a need to use the device in the frequency different from the factory default, change the value of this Parameter
according to the frequency list below. Modification is possible only while the HE-TPS04 is not included to Z-Wave
network.
Note
: The factory default frequency differs depending on which region the device was intended for sale in. Check the
factory default frequency on the device plate or on the packaging.
Note
: Do not change this Parameter value if there is no special need.
Note
: If change the value of this Parameter, the frequency change will be applied only after removing the device from
Z-Wave network (the device will automatically reboot)
.
Note
: The change of this Parameter will result in inability to control the device, if the device was included to the
controller/gateway which supports only one frequency.
Note
: Resetting the device to factory default settings will revert the frequency to the factory default value.
Note
: In most of countries it is not allowed to use the frequency different from the frequency intended for that country.
Frequency list for different regions:
0: EU (868.4 MHz, 869.85 MHz)
1: US (908.4 MHz, 916.0 MHz)
2: ANZ (919.8 MHz, 921.4 MHz)
3: HK (919.8 MHz)
4: IN (865.2 MHz)
5: IL (916.0 MHz)
6: RU (869.0 MHz)
7: CN (868.4 MHz)
8: JP (922.5 MHz, 923.9 MHz, 926.3 MHz)
9: KR (920.9 MHz, 921.7 MHz, 923.1 MHz)
The full list of Z-Wave global regions where Z-Wave works is available at