7. Cables and fuses for heaters 1106
– XX (SKLF / Octa)
Model
power
kW
Sauna heaters connec-
tion cable H07RN-F/
60245 IEC 66
mm²
400V
– 415V 3N~
Fuce
A
1106
– 901
9,0
5 x 2,5
3 x 16
1106
– 1050
10,5
5 x 2,5
3 x 16
1106
– 1201
12,0
5 x 6
3 x 25
1106
– 1501
15,0
5 x 6
3 x 25
Table 4. Kables and fuses for heater 1106
– XX (SKLF / Octa)
8. Using the contactor cases
The contactor case 2005
– 40 (WE – 40), can be used with the following sauna heaters:
- SKLE -
.…
1105 -
….
9 KW 230V 3~
- SKLE -
.…
1105 -
….
9
– 15 KW 400V – 415V 3N~
- Laava -
.…
1105 -
….
9 KW 230V 3~
- Laava -
.…
1105 -
….
9
– 15 KW 400V – 415V 3N~
- Octa -
….
1106 -
….
9
– 15 kW 400V – 415V 3N~
The models of the control panels that can be used to control contactor cases WE 40. 31 (Trend) and 33 (Premium
Wifi).
Refer to the control panel operating manual for more specific instructions.
The contactor box is intended to be installed outside the sauna room
.
The cables must be installed using a fixed
installation. A connection box must be installed in the sauna room with a semi-fixed installation on the sauna
heater.
Failure to follow the minimum clearances in the installation instructions may cause a fire hazard.
Always check the sauna room before switching the sauna heater on.
9. Locating the connecting box for the connection cable in the sauna room
2
0
0
m
m
A
A
3.
2.
1.
5
0
0
m
m
5
0
0
m
m
Figure 4. Location for the connection box
A = Specified minimum safety clearance, see table 1, 2 or 3
1. Recommended location for the connecting box
2. Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The
connection box must be clear of obstacles. When installing the connection box to zones 2 or 3,
refer to the instructions and regulations of the local energy supplier.
User and installation manual
WE 40
7