1.  Preparing for sauna heater installation

 

 

Check the following before installing the sauna heater. 

-   The ratio of the heater's input (kW) and the sauna room's volume (m

3

). Volume recommendations are presented  

     in Tables 1 and 3 on page 5 and 6. The minimum and maximum volumes must not be exceeded. 

 
-   The height of the sauna room must be at least 1900 mm or 2100 mm depending on the heater power. 

-   Uninsulated and masonry stone walls extend the preheating time. Each square metre of plastered ceiling or wall  
    surface adds 1.2 m

3

 to the sauna room's volume. 

 
-   Check page 6 and 7 Table 2 and 4 for a suitable fuse size (A) and the correct diameter of the power supply cable  
     (mm²) for the sauna heater in question. 

 
-   Conform to the specified safe clearance around the sauna heater. 

-   There should be enough room around the control panel for maintenance purposes. Also a doorway can be    
    considered as a maintenance area. 

 

 

2.  Installation

 

 
Follow the safety clearance specifications on pages 5 and 6 on tables 1 and 3 when installing the sauna heater.  

The sauna heater is a floor-standing model. The base must be solid, because the sauna heater weighs  
about 90 kg. 

The sauna heater is levelled by the adjustable legs.  

The sauna heater is fixed on the floor from its legs by the provided metal fasteners (2 pcs). This will keep the safety 
clearances intact during use. 

Walls or ceilings must not be clad with fibre-reinforced plaster board or other light-weight cladding, because they 
may cause a fire hazard. 

 

Installing the sensor near a supply air vent

 

 
The sauna room air should be exchanged six times in an  
hour. The diameter of the supply air pipe should be  
between 50 and 100 mm. 

 
A circular air supply vent (360°) must be  
installed at least 1000 mm  away from the sensor. 

 

An air supply vent with a flow-directing panel 
(180°) must be installed at least 500 mm away from  
the sensor. Air flow must be directed away from the  
sensor. 

 

3.  Ceiling installation of the sensor

 

 

In ceiling installation, a 5-mm hole must be drilled to the  
sensor case to allow any condensed water to drain. 
Do not spray water directly towards the sensor or splash  
water at it with a sauna scoop. 

 

 

Installing the Extra NTC sensor 

 
The additional OLET 31 sensor is connected to the Ext NTC connector on the RJ10 circuit board. For more details, 
refer to the switch diagram. The additional sensor is installed on the sauna room wall no more than 500 mm from 
the ceiling. Once the additional sensor has been connected to the circuit board, it is automatically activated. This 
means that the temperature shown on the control panel is measured by the additional sensor. 
The primary sensor installed above the sauna heater only has the limiter circuit that limits the maximum tempera-
ture to 110 °C. Even if the temperature is set to 110 °C on the control panel, the maximum temperature that can be 
shown on the panel is approximately 90 °C, as the primary sensor above the heater limits the maximum tempera-
ture to 110 °C. Depending on individual preferences, the temperature of a sauna room is typically set between 70 
and 80 °C.

 

 
 
 

Ø 5mm 

User and installation manual  

WE 40

 

360°

1000 mm

180°

500 mm

Sensor 

Sensor 

Содержание WE 40

Страница 1: ...Contactor box WE 40 2005 40 Control panels Premium Wifi 1601 33 Trend 1601 31 Premium Wifi Trend Contactor box WE 40 314 SYWE 32 3 A User and installation manual WE 40 REWARD YOURSELF...

Страница 2: ...5 ROHS 11 Figure and Tables Figure 1 Installation location of the OLET 31 5 Figure 2 Alternative installation location of the OLET 31 5 Figure 3 Safety clearances to heater SKLF Octa 6 Figure 4 Locati...

Страница 3: ...aring for sauna heater installation 1 3 Operation of the sauna heater controls This appliance may not be used by children aged less than eight years by persons with reduced physical sensory or mental...

Страница 4: ...ire hazard Installing the sensor near a supply air vent The sauna room air should be exchanged six times in an hour The diameter of the supply air pipe should be between 50 and 100 mm A circular air s...

Страница 5: ...sor 40 mm from the ceiling in the centre of the heater The safety distance between the heater and the wall behind the heater must be at least the minimum dis tance listed in tables 1 Figure 2 Alternat...

Страница 6: ...afety clearances min Adequate amount of stones kW Volum m3 Min height H mm On the sides A mm In front D mm To the ceiling F mm Approx kg 9 0 10 5 12 0 15 0 8 13 9 15 10 18 14 24 1900 1900 2100 2100 25...

Страница 7: ...alled outside the sauna room The cables must be installed using a fixed installation A connection box must be installed in the sauna room with a semi fixed installation on the sauna heater Failure to...

Страница 8: ...Helo recommends using the Tyl Helo model with product number 0043233 SSTL 8260371 When the door switch is installed on the bottom part of the door Tyl Helo recommends using the Tyl Helo model with pr...

Страница 9: ...ontact Signalkontakts Elektrik tte kontakt Sterowanie ogrzewaniem elektrycznym 4 Saunavalo Bastu belysning Saunabeleuchtung Sauna light Sauna icht max Ampoule du sauna max Sauna swiatla Pirts apgaismo...

Страница 10: ...tactor box WE 40 Control panel 1601 31 4 3 2 1 Contactor box WE 40 OLEA 103 1 Blue 2 White 3 Red 4 Yellow Terminal block Limiter Sensor cable Sensor OLET 31 Door switch NOTE See more detailed installa...

Страница 11: ...0 10 5 12 0 15 0 354 17 M SKLE SEPC 11 2000W SEPC 12 1500W SEPC 10 2500W 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 3 5 2 4 6 N L L L 1 2 3 4 5 6 1 2 3 Yksi tehoryhm En effekt grupp One effektgroup Ein Stu...

Отзывы: