2.7.   If the sauna heater will not heat up 

 

If the sauna heater will not heat up, please check that: 

-   the power is on; 
-   the main fuses of the sauna heater are intact; 
-   is there any error messages on the control panel. In case of an error message on the control panel,  
     please refer to the control panel instructions. 

 

THE PERSON INSTALLING THE SAUNA HEATER SHOULD LEAVE THESE INSTRUCTIONS AT THE PREMISES  

 

FOR THE FUTURE USER. 

 

2.8.   Preparing for sauna heater installation 

 

 

Check the following before installing the sauna heater. 

 

-   The ratio of the heater's input (kW) and the sauna room's volume (m

3

). Volume recommendations are presented in  

 

    Table 1 on page 6. The minimum and maximum volumes must not be exceeded. 

 
 

-   The sauna room height must be a min. of 1900 mm. 

 

-   Uninsulated and masonry stone walls extend the preheating time. Each square metre of plastered ceiling or wall surface  

 

    adds 1.2 m

3

 to the sauna room's volume. 

 
 

-   Check page 8 Table 2 for a suitable fuse size (A) and the correct diameter of the power supply cable (mm²) for the  

 

    sauna heater in question. 

 
 

-   Conform to the specified safe clearance around the sauna heater. Please refer to page 6. 

 

-   There should be enough room around the control panel for maintenance purposes. Also a doorway can be considered  

 

    as a maintenance area. 

 

2.9. Installation 

 
Follow the safety clearance specifications on page 6 and 7 when installing the sauna heater.  

The sauna heater is a floor-standing model. The base must be solid, because the sauna heater weighs about 120 kg. 

The sauna heater is levelled by the adjustable legs.  

The sauna heater is fixed on the floor from its legs by the provided metal fasteners (2 pcs). This will keep the safety clear-
ances intact during use. 

Mounting of the sauna heater to the wall or the sauna benches available as an accessory (metal fastenings. S-ZH 58, 
0043272). 

Walls or ceilings must not be clad with fibre-reinforced plaster board or other light-weight cladding, because they may 
cause a fire hazard. 

Only a single sauna heater is allowed per sauna room. 

 
 

2.10.  Sauna heater safety clearances 

 
 
 

 

 

 

 

 

  

 
 
 
 
 
 
 
 

 
 

Table 1  Safety clearances 
 

 

 
 
 

Out-

put 

Sauna room 

Heater minimum clearances 

Amount of 

stones 

 
 
 
 
 

kW 

Volume 

Height 

From 

side to 

wall 

 

mm 

From 

front to 

sauna 
bench 

mm 

 
To ceil-
ing 

 

 

mm 

In kg, approx. 

min. 

m³ 

max. 

m³ 

 

min. mm 

6.8 

1900 

60 

60 

770 

100 

10.5 

15 

1900 

60 

60 

770 

100 

Installation and User Manual  

Rocher DES

 

 

Содержание Rocher DES

Страница 1: ...AUNA HEATER 1102 70 040517 1102 105 040517 230V 240V 1N 2 230V 3 400V 415V 3N CONTROL PANEL 1601 31 RA 31 Trend 1601 33 RA 33 Premium Wifi 314 SKLT 68 3 A Installation and User Manual Rocher DES REWAR...

Страница 2: ...ng toggle 10 2 16 Locating the connecting box for the connection cable in the sauna room 11 2 17 Remote controlling 11 2 18 Door switch 12 2 19 Wiring diagram 13 2 20 Principle image when 1601 31 RA 3...

Страница 3: ...e safe use of the device and the risks involved Children must not be allowed to play with the appliance or to clean and service it without supervision 7 12 EN 60335 1 2012 2 1 Sauna room The walls and...

Страница 4: ...ZONE C IF THE SAUNA HEATER S CONTROL THERMOSTAT IS LOCATED IN THE SAME ZONE 2 4 Installing the sensor near a supply air vent The sauna room air should be exchanged six times in an hour The diameter o...

Страница 5: ...ompartment regularly at least once a year in private use remove small and broken stones and replace them with new ones In commercial use this operation must be performed at least every second month St...

Страница 6: ...arance around the sauna heater Please refer to page 6 There should be enough room around the control panel for maintenance purposes Also a doorway can be considered as a maintenance area 2 9 Installat...

Страница 7: ...ture using a wall support The OLET 28 sensor is always installed on the ceiling Figure 2 Safety clearances Installation and User Manual Rocher DES 7 1900 60 mm 60 770 40 1130 A D F H mm 60 60 425 mm O...

Страница 8: ...m its normal position Lift off the support bars Pile stones up to the Helo marker Reinstall the support bars Install the support bars as above in the reversed order Pile the stones so that they cover...

Страница 9: ...ings Tilt the support and press the pivots at each end of the support to the grooves in the inside of the heater s vertical beams one end at a time The support for heating elements should stay levelle...

Страница 10: ...F 60245 IEC 66 mm 230V 1 N 2 Fuse A 6 8 5 x 1 5 3 x 10 4 x 4 3 x 20 3 x 6 1 x 35 10 5 5 x 2 5 3 x 16 4 x 6 3 x 35 Table 2 Connection cable and fuses NOTE Controlling the lights in the sauna with the...

Страница 11: ...power button or via a normally open contact Remote control can be pulsed or it can always remain on NOTE Heater regulations require door switches if the heater is turned on from outside of the sauna...

Страница 12: ...Door switch instructions for installation and connection The door switch is installed outside the sauna room on the upper edge of the door at least 300 mm from the inner corner The switch part is inst...

Страница 13: ...ct signaalcontact Signal kontakts Elektrik tte kontakt Wisselschakelaar elektrische verwarming Sterowanie ogrzewaniem elekt rycznym 3 Saunavalo Bastu belysning Saunabeleuchtung Sauna light Sauna icht...

Страница 14: ...llow A2 Green A3 Red A4 Black Adapter circuit board OLEA 102 Control panel 1601 31 Sensor cable Sensor OLET 28 Limiter 1 Blue 2 White 3 Red 4 Yellow Adapter circuit board OLEA 102 Principle image Sens...

Страница 15: ...103 1 1 3 5716203 Finder relay 2 2 4 7801711 Fuse 1 AT 1 1 4 7801710 Fuse 3 15 AT 1 1 5 7817536 Fuse holder 2 2 6 6101741 Rocker switch OAAA 2 1 1 7 7306008 Rubber cover for rocker switch 1 1 8 520777...

Страница 16: ...ental protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical and ele...

Отзывы: