2.9.2 Sauna heaters safety clearances
Image 3 Safety clearances
Table. 1 Safety clearances
Effect
kW
Heater connection cable
H07RN –F/ 60245 IEC 66
mm²
400V - 415V 3N~
Fuse
A
4,5
5 x 1,5
3 x 10
6,0
5 x 1,5
3 x 10
8,0
5 x 2,5
3 x 16
9,0
5 x 2,5
3 x 16
Table. 2 Heater connection cable and fuse
Effect Sauna
room
Heaters minimum clearance (mm)
Stone
kW
Volume Height
Side
wall
A
mm
In front of
D
mm
To ceiling
mm
To the
floor
K
mm
B
mm
J
mm
min. max.
Approx Approx
kg kg
min.
m³
max.
m³
min. mm
4,5 3 6 1900 40
80
1100 120 135
245 20 28
6,0 5 9 1900 45 100
1100 120 140
245 20 35
8,0 8 12 1900 75 130
1100 150 170
275 20 35
9,0 9 13 1900 80 150
1100 150 175
275 20 35
J
1
50
280 B
Product Manual
Havanna STS
9
Drill. Ø3,5 mm
Screw 6 x 40 (2 kpl)
Screw 6 x 16 (2 kpl)
(mm)
min
30
min
20
min
20
K
A 475 A
min
30
50
5
m
in
11
00
m
in
1
900
300 D
(mm)
Minimum distances for the
mounting bracket (mm)