Helo FONDA DET Скачать руководство пользователя страница 5

 

 

 

 

2.5  Sauna heaters stones 

 

     Quality stones meet the following requirements: 
 
-    Sauna stones should withstand heat and heat variation caused by vaporisation of the water thrown on  
 

the stones. 

 
-   Stones should be rinsed before use in order to avoid odour and dust. 
 
-   Sauna stones should have an uneven surface to supply a larger surface for the water to evaporate from. 

 

-   Sauna stones should be large enough, measuring about 50

100 mm to allow good ventilation between the 

stones.  This extends the useful life of the heating elements. 

 
-   Sauna stones should be piled sparsely in order to enhance ventilation between the stones. Do not bend 

the heating  elements together or against the frame. 

 
-   Rearrange the stones regularly (at least once a year) and replace small and broken stones with new, larg-

er stones. 

 
-   Stones are piled so that they cover the heating elements. Do not, however, pile a large heap of stones on 

the heating elements. For a sufficient amount of stones refer to Table 1 on page 7. Any small stones in the 
package of stones must not be piled on the sauna heater. 

 
-   The warranty does not cover defects resulting from poor ventilation caused by small and tightly packed 

stones.          

 
-    Structural clay tiles are not allowed. They may cause damage to the sauna heater that will not be covere 
 

by the warranty. 

 

Do not use soapstone as sauna rocks. Any damages resulting from this will not be covered by the stove  

      warranty. 
 

Do not use lava stone as sauna rocks. Any damages resulting from this will not be covered by the stove  

      warranty. 
 

-     DO NOT USE THE HEATER WITHOUT STONES.

 

 

 

 
 

 
 

 
 

 
 

 
 

 

2.6  Electric heating toggle 

 
Electric heating toggle applies to homes with an electric heating system. 
 
The sauna heater thermostat also controls the heating toggle. In other words, home heating turns on once the 
sauna thermostat cuts power off the sauna heater. 
 
 
 
 

 

Installation and User Manual  

FONDA DET

 

 

Содержание FONDA DET

Страница 1: ...ELECTRIC SAUNA HEATER 1712 450 040518 1712 600 040518 1712 800 040518 CONTROL PANEL 1601 27 RA 27 T1 1601 34 RA 34 EC50 314 SKSM 208 2 A Installation and User Manual FONDA DET REWARD YOURSELF...

Страница 2: ...stallation of control unit and sensor 8 3 4 Connection of the sauna heater to the mains 8 3 5 Location for the connection box 9 3 6 Principle image when T1 is used as control panel 10 3 7 Door switch...

Страница 3: ...ll insulated All surfaces that store heat such as tiled and plastered surfaces must be insulated It is recommended to use wooden panel cladding inside the sauna room If there are heat storage elements...

Страница 4: ...ilation In this case the exhaust valve is installed min 1m higher than the inlet valve DO NOT ISTALL INLET VALVE WITHIN ZONE C IF THE SAUNA HEATER S CONTROL THERMOSTAT IS LOCATED IN THE SAME ZONE 2 4...

Страница 5: ...he heating elements Do not however pile a large heap of stones on the heating elements For a sufficient amount of stones refer to Table 1 on page 7 Any small stones in the package of stones must not b...

Страница 6: ...olume Check page 8 Table 2 for a suitable fuse size A and the correct diameter of the power supply cable mm for the sauna heater in question Conform to the specified safe clearance around the sauna he...

Страница 7: ...minimum mm Side wall A mm In front of D mm Ceiling F mm Floor K mm ca kg 4 5 6 0 8 0 4 6 5 9 8 12 1900 1900 1900 50 50 50 50 50 50 1150 1150 1150 100 100 100 20 20 20 Screws 6 x 40 2 pcs Screws 6 x 16...

Страница 8: ...se H07RN F 60245 IEC 66 cables or a corresponding type Other output cables signal lamp electric heating toggle must also adhere to these recommendations Do not use PVC insulated cable as a connection...

Страница 9: ...ded in this area 3 This area should be avoided Always use a silumin box In other areas use a heat resisting box T 125 C and heat resisting cables T 170 C The connection box must be clear of obstacles...

Страница 10: ...Yellow Limiter Connector strip Heater Heater Sensor OLET 28 Control pannel T1 11 Valk Vit White Weiss 12 Musta Svart Black Schwarz 13 Vihre Gr n Green Gr n 14 Kelt Gul Yellow Gelb 15 Harm Gr Grey Gra...

Страница 11: ...timer must have a door switch The control panel T1 and EC 50 can be fitted with either a Helo DSA 1601 35 RA 35 door switch adapter item number 001017 or a Helo door switch adapter item number 0043233...

Страница 12: ...trique contact de signal Signal kontakt Signal contact Wisselschakelaar elektrische verwarming signaalcontact Signalkontakts Elektrik tte kontakt Sterowanie ogrzewaniem elektrycznym 3 Saunavalo Bastu...

Страница 13: ...7812550 1 1 1 5 Relay Finder NRFA 3 2 5716203 2 2 2 6 Rocker switch OAAA 2 6101741 1 1 1 7 Rubber cover for rocker switch 7306008 1 1 1 8 Fuse holder NSPJ 2 7817536 2 2 2 9 Fuse F1 T1AH 7801711 2 2 2...

Страница 14: ...ental protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical and ele...

Отзывы: