Helo Cava series Скачать руководство пользователя страница 2

 

2

 
 
 
 

FIXING THE HEATER TO THE WALL. 
 
Once the adjustable legs are turned in the  
fixing height of the heater, wall rack is 750mm  
from the floor. The adjustable legs have a 15mm  
adjustment allowance just in case the floor is on  
an incline. 
Check after fixing to the wall that both adjustable  
legs are evenly set against the floor. 
 
 
The measurement between the fixing holes of the  
rack to be fixed on the wall is 240mm. 
 
 
 
Wall fixing parts: 
   - locking pieces for the heater (A)  2 pieces 
   - wall fastener (B) 

 

1 piece 

   - metal screw 4.2 x 13mm 

2  pieces 

   - cover screw 6 x 40mm 

2 pieces 

 
Fit the locking pieces (A) for the heater into the 
holes in the back plate so that the entering part 
turns upwards. 
 
 
 
 
Fix the wall rack (B) to face the wall so that the 
holes where the locking pieces are fixed will be 
upwards. The rack can also be fixed directly to 
the heater. Mark in advance the locations of the 
screws to the wall and, if needed, drill small 
guide holes and then fix the heater to the wall 
with the screws supplied. 
 
 
 
 
 
 
The illustration shows how the wall rack should 
be fixed in the heater. 
 
 
 
 
 
The parts in the heater are fixed to the wall rack 
with metal screws. 
 

A

B

240 mm

Drill diameter o 3,5 mm

M

in

 75

0 mm 

 M

ax 

765 

mm

Min.
240 mm

240

Содержание Cava series

Страница 1: ...r circulation through the stones is affected When replacing the stones new stones have to be of a high quality NOTE The heater stones MUST NOT be placed in the space between the front soapstones and t...

Страница 2: ...l screw 4 2 x 13mm 2 pieces cover screw 6 x 40mm 2 pieces Fit the locking pieces A for the heater into the holes in the back plate so that the entering part turns upwards Fix the wall rack B to face t...

Страница 3: ...the heater to approx a 50 C setting for about an hour Then switch off the heater and let the stones cool down 2 The second heating Set the heater to approx a 80 C setting for about an hour Then switch...

Страница 4: ...inlet valve DO NOT ISTALL INLET VALVE WITHIN ZONE C IF THE SAUNA HEATER S CONTROL THERMOSTAT IS LOCATED AT THE SAME ZONE Heater installation measurements All the measures are minimum distances unless...

Страница 5: ...g med elv rme Signal kontakt Signal contact Contact du signal Signaalcontact Contacto se al 5 Ohjauskeskus Styrpanel Steuerger t Control panel Panneau de commande Bedieningspaneel Panel de control 6 T...

Страница 6: ...230V 1N 230V 2 230V 3 400V 3N Heater Principal wiring diagram N N 55 Sauna light 230V 100W Fan 230V 100W Electrical heating Control 230V NOTE Not with the RA 18 Midi control centre or RA 16 Easy cont...

Страница 7: ...they are placed Install the intermediate pieces 8 of the soapstones so that the projection will always stay on the stone i e there will always be an air gap between the stones The metal pieces are pla...

Страница 8: ...alled Install the metallic supports between the vertical limiters The soapstones also remain between the vertical limiters End limiter The illustration shows the installed supports The soapstones are...

Страница 9: ...at the back remain where they are The illustration shows both the vertical and horizontal limiters of the soapstones Install the middle stones The length of the middle stones is 405mm Push the stone f...

Страница 10: ...ctions for environmental protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of...

Отзывы: