INSTALLATION AND USER INSTRUCTIONS 

 
ELECTRICAL SAUNA HEATER:

   1118-60-0405 

   1118-90-0405 

 

Can be connected to the following control unit: 

 

 RA 18  Midi control unit  
 RA 12  Digi II control unit 
 RA 13  Digi I control unit 
 RA 16  Easy control unit 
 

INSTALLATION OF THE SAUNA HEATER 

The following points have to be observed when installing the heater: 

-

 

Adhere to the given installation measurements. 

-

 

Wood panelling is recommended as material for the walls and ceiling of the sauna. 

-

 

Ensure that the panel wall has been reinforced at the point of the fixing screws. 

-

 

Only one heater may be installed into a sauna. 

-

 

The heater must only be connected to the mains by a qualified person as defined by current 
electrical safety regulations. 

 

NOTE! 

Prior to switching the heater on, ensure that the sauna room is ready for heating.

 

 
CONNECTING THE HEATER TO THE MAINS 

The heater is semi-connected to the mains with H07RN-F (VSN) or A07BB-F(VSB) rubber cable.  

 
HEATER STONES 

We recommend that the heater stones are cleaned before placing them in the heater. The largest stones are placed at 
the bottom and the smallest on the top. Stones must not be loaded too tightly, or air circulation is inhibited. Nor must 
the stones be placed so that heating elements become wedged together or against the heater body. The stones must 
completely cover the heating elements. The stones have to be replaced at the latest when they start to crumble, 
because otherwise the air circulation through the stones is affected. When replacing the stones, new stones have to 
be of a high quality. 

 
NOTE!  
- The heater stones MUST NOT be placed in the space between the front soapstones and the first heating 
element. 
- Before using the heater check that the soapstones in the heater are undamaged and installed according to 
instructions.

 

Otherwise the use of the heater is prohibited. The guarantee does not cover faults due to poor 

air circulation caused by small and tightly packed stones.

 

Ceramic stones may damage the heater.

 

The 

guarantee of the heater does not cover any damage caused by the use of ceramic stones. 

 

INSTALLATION OF THE CONTROL UNIT AND SENSOR ELEMENTS

 

The control unit is electrically connected via a cable to the heater. The control unit is intended for installation in the 
sauna room or outside of it, depending on the model of the control unit. Check the control unit location from the control 
unit installation and user instructions. 
The sensor is fixed to the wall of the sauna, directly on the middle line of the heater, 40mm from the ceiling. Any 
deviation from the given installation measurements will cause a risk of fire. 
The temperature limiter in the sensor element cuts off all the electricity to the heating elements if the heater 
temperature increases to a level where it causes a danger to the wooden parts of the sauna. Once the temperature is 
reduced the limiter can be restored by pressing the reset button. 

Before pressing the reset button, the reason for the triggering of the temperature limiter must always be 
clarified!

 

 

 

7013487   314 SKLT 7 C 

 
 

Main switch

Restore

Sensor OLET 19

Содержание Cava series

Страница 1: ...r circulation through the stones is affected When replacing the stones new stones have to be of a high quality NOTE The heater stones MUST NOT be placed in the space between the front soapstones and t...

Страница 2: ...l screw 4 2 x 13mm 2 pieces cover screw 6 x 40mm 2 pieces Fit the locking pieces A for the heater into the holes in the back plate so that the entering part turns upwards Fix the wall rack B to face t...

Страница 3: ...the heater to approx a 50 C setting for about an hour Then switch off the heater and let the stones cool down 2 The second heating Set the heater to approx a 80 C setting for about an hour Then switch...

Страница 4: ...inlet valve DO NOT ISTALL INLET VALVE WITHIN ZONE C IF THE SAUNA HEATER S CONTROL THERMOSTAT IS LOCATED AT THE SAME ZONE Heater installation measurements All the measures are minimum distances unless...

Страница 5: ...g med elv rme Signal kontakt Signal contact Contact du signal Signaalcontact Contacto se al 5 Ohjauskeskus Styrpanel Steuerger t Control panel Panneau de commande Bedieningspaneel Panel de control 6 T...

Страница 6: ...230V 1N 230V 2 230V 3 400V 3N Heater Principal wiring diagram N N 55 Sauna light 230V 100W Fan 230V 100W Electrical heating Control 230V NOTE Not with the RA 18 Midi control centre or RA 16 Easy cont...

Страница 7: ...they are placed Install the intermediate pieces 8 of the soapstones so that the projection will always stay on the stone i e there will always be an air gap between the stones The metal pieces are pla...

Страница 8: ...alled Install the metallic supports between the vertical limiters The soapstones also remain between the vertical limiters End limiter The illustration shows the installed supports The soapstones are...

Страница 9: ...at the back remain where they are The illustration shows both the vertical and horizontal limiters of the soapstones Install the middle stones The length of the middle stones is 405mm Push the stone f...

Страница 10: ...ctions for environmental protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of...

Отзывы: