THE HEATERS MINIMUM DISTANCES
Power Sauna room Minimum distance to:
Stones Supply connections
Volume Height Side wall In front of Ceiling Floor From junction box to the heater
HO7RN-F
min max min max 230V 230V 230V 400V
Approx Approx 3~ 2~ 1N~ 3N~
kW m m min.mm mm mm mm mm kg kg mm mm mm mm
4,5 3 6 1900 40 80 1100 120 20 28 4 x 2,5 3 x 4 3 x 4 5 x 1,5
6,0 5 9 1900 45 100 1100 120 20 35 4 x 2,5 3 x 10 3 x 10 5 x 1,5
8,0 8 12 1900 75 130 1100 150 20 35 4 x 6 3 x 10 3 x 10 5 x 2,5
9,0 9 13 1900 80 150 1100 150 20 35 4 x 6 5 x 2,5
J
1
50
280 B
Minimum distances for the mounting
bracket (mm)
Drill 3,5 mm
Screws 6 x 40 (2pcs)
Screws 6 x 16 (2pcs)
min
2
0
min 30
min 30
m
in
3
0
min
30
min
20
min
20
K
A 475 A
min
30
50
5
F
m
in 19
00
300 D
Heater Minimum distance (mm)
kW A B D J K
4,5 40 135 80 245 120
6,0 45 140 100 245 120
8,0 75 170 130 275 150
9,0 80 175 150 275 150