INSTALLATION AND OPERATING INSTRUCTIONS
72-0106 01-07-16
7013482 314 SKSM 215 A
Page 2
DIAGRAM 1
MOUNTING BRACKET LOCATION AND MINIMUM DISTANCE TO COMBUSTIBLE MATERIAL
C
High Limit Control
D
2"
1"
18½"
74"
Minimum
Screws
6"
14 3/8" B
10½"
Use the long screws in the upper
holes of the mounting bracket
A
6½"
Min.
5"
Temperature
Sensor
44"
Minimum
Guard
Rail
(Upper Bench)
K
Recheck your distances from the heater to
combustible materials to be sure you have
the proper minimum distances.
NOTE 1: Use separate 120 volt branch circuit protected for 15 amps if control switch is to be used for lighting.
DIAGRAM 2
OBSERVING MINIMUM DISTANCES IS REQUIRED
TO REDUCE THE RISK OF FIRE
"A"
DISTANCE
"B"
DISTANCE
"C"
DISTANCE
"D"
DISTANCE
"K"
DISTANCE
Designer 4.5
3.0"
3 5/8"
4.0"
11 1/2"
23"
Designer 6.0
4.0"
4 5/8"
5.0"
11 1/2"
23"
Designer 8.0
5.0"
5 5/8"
6.0"
11 1/2"
23"
HEATER
MINIMUM
WIRE SIZE
Floor Area
Ceiling
Height
Volume
Cu.Ft.
Ceiling
Height
Volume
Cu.Ft.
Power Supply
to Heater
1
208
21.6
2 #10AWG+GR
1
240
18.8
2 #10AWG+GR
3
208
12.5
3 #12AWG+GR
3
240
10.8
3 #12AWG+GR
1
208
28.8
2 #8AWG+GR
1
240
25
2 #10AWG+GR
3
208
16.7
3 #12AWG+GR
3
240
14.4
3 #12AWG+GR
1
208
38.5
2 #8AWG+GR
1
240
33.3
2 #8AWG+GR
3
208
22.2
3 #10AWG+GR
3
240
19.2
3 #10AWG+GR
AMPS
Light
Circuit
Supply
Designer
Trend 4.5
1712-45-1706
4.5
12 sq. ft.
74"
100
96"
210
S
e
e
N
o
t
e
1
B
e
l
o
w
HEATER
MODEL
/
Product
Number
KW
MINIMUM ROOM
MAXIMUM ROOM
PHASE
VAC
310
Designer
Trend 8.0
1712-80-1706
8.0
31 sq. ft.
74"
250
96"
425
Designer
Trend 6.0
1712-60-1706
6.0
21 sq. ft.
74"
175
96"