background image

 

 

 
 

2.17   BWT technology in a Roxx Premium heater 

 

Bio Water Technology (BWT) uses the heater's thermal energy to heat water and raise the moisture level without 
a separate heat source. Moisturised air improves the sauna climate, and various fragrances and salts can be 
evaporated to make the sauna experience more enjoyable.

 

 

A water container with a lid is delivered with the heater; the container can be installed between the heating elements. 
The water tank can be installed when approximately 2/3 of the heater stones have been stacked. The water tank, even 
when empty, does not need to be removed when the heater is on.  
The tank has a capacity of approximately two litres. Bringing water to the boil when the tank is full takes approximately 1-
2 hours depending on the set temperature. 
It is recommended to pour water into the tank when the heater is turned off. Water is poured through the grate on the lid. 
You can pour less water into the tank if the bathing time is shorter.  

The water tank must be removed and impurities, such as limescale etc. removed every so often. The stones surrounding 
the tank must be removed during cleaning, so that the tank can be lifted more easily. 

When the water is boiling, the moisture levels in the sauna remain high. This means that the temperature can be kept 
lower while still experiencing pleasant heat. More heat and moisture can, if necessary, be created by throwing water on 
the stones on top of the heater. 

Mild fragrance essences, suitable for heater use, can be put in the water tank. 
You can, for example, put mountain salt crystals on the lid of the water tank. They dissolve into the steam and evaporate 
into the air. If mountain salt crystals are placed in the water tank, the salinity of the water will remain 26%. 
 
 

 

3.  Helo Roxx Premium  spare part list 

 

     

 

 
 
 

Tabel 5   Roxx Premium  Spare parts list 

Part 

Part number 

Part name 

Helo Roxx 60 Premium 

Helo Roxx 90 Premium 

4071002 

Rock gate 

5916324 

Circuit board OLEA 103 

7712000 

Strain relief 

7812550 

Mains connector  NLWD 1-1 

6214042 

Thermostat OLET 31 

4316221 

Heating element SEPC 64 

5207518 

Heating element SEPC 65B 

 

5320517 

Contactor OKTA 5-1 

6119649 

Rocker switch 

7306611 

Rubber cover for rocker switch 

15 

Installation and User Manual  

HELO Roxx Premium

 

Содержание 1107-60-040517

Страница 1: ...A HEATER 1107 60 040517 1107 90 040517 230V 240V 1N 2 230V 3 400V 415V 3N CONTROL PANEL 1601 31 RA 31 Trend 1601 33 RA 33 Premium Wifi 314 SKLT 72 3 A Installation and User Manual HELO Roxx Premium RE...

Страница 2: ...2 12 Heating the sauna 11 2 13 Sauna heater stones 12 2 14 If the sauna heater will not heat up 12 2 15 Door switch 13 2 16 Principle image when RA 33 Premium is used as control panel 14 2 17 BWT tech...

Страница 3: ...these elements may extend the pre heating period even though the sauna room is otherwise well insulated see page 4 section 1 Preparing for sauna heater installation 1 3 Operation of the sauna heater...

Страница 4: ...should be enough room around the sauna heater controls for maintenance purposes Also a doorway can be considered as a maintenance area Only a single sauna heater is allowed per sauna room 2 1 Installa...

Страница 5: ...edges A through the holes in the heater so that the ingoing part is turned upwards The wall mount B is attached to the wall so that the holes where the locking wedges are secured to are upwards The mo...

Страница 6: ...nsor is installed on the sauna room wall no more than 500 mm from the ceiling Once the additional sensor has been connected to the circuit board it is automatically acti vated This means that the temp...

Страница 7: ...bove the heater and in line with the centre line of the heater Do not install the sensor anywhere else 100 490 100 10 280 D 10 40 100 490 100 10 280 D 10 40 Sensor OLET 31 Sensor OLET 31 Sensor OLET 3...

Страница 8: ...uses NOTE Controlling the lights in the sauna with the circuit board is only possible with resistive loads incandescent light bulbs The circuit board relay cannot withstand capacitive loads switched m...

Страница 9: ...rs 3 and 4 of a RJ10 circuit board The recommended cable size is AWG 24 or 26 The maximum length of an AWG 24 cable is 200 m when using a Trend controller The maximum length of an AWG 26 cable is 130...

Страница 10: ...k l mmityksen vuorottelu Alternering med elv rme Signal kontakt Signal contact Contac t du signal Signaalcontact Contacto se al 3 Saunavalo Bastu belysning Saunabeleuchtung Sauna light clairage du sau...

Страница 11: ...THERMOSTAT IS LOCATED IN THE SAME ZONE 2 12 Heating the sauna Before turning the sauna heater on make sure the sauna room is suitable for taking a sauna bath When heated for the first time the sauna h...

Страница 12: ...iled so that they cover the heating elements Do not however pile a large heap of stones on the heating elements For a sufficient amount of stones refer to Table 1 on page 6 Any small stones in the pac...

Страница 13: ...r edge of the door at least 300 mm from the inner corner The switch part is installed on the door frame and the magnet is installed on the door The distance between the switch and the magnet is 18 mm...

Страница 14: ...cuit board OLEA 103 1 Blue 2 White 3 Red 4 Yellow End stop return acknowledgement Adapter circuit board OLEA 103 RJ10 intermedia cable Heater Control panel RA 33 Premium Control panel RA 33 Premium Se...

Страница 15: ...emoved every so often The stones surrounding the tank must be removed during cleaning so that the tank can be lifted more easily When the water is boiling the moisture levels in the sauna remain high...

Отзывы: