background image

 

 

 
 
 
 
 
 
 
 

ELECTRIC SAUNA HEATER: 
 

1107 

 60 

 040517 

1107 

 90 

 040517 

230V 

 240V 1N~ / 2~ 

230V 3~ 
400V 

 415V 3N~ 

 

  

CONTROL PANEL: 

 
1601 

 31  (RA 

 31) Trend)  

1601 

 33  (RA 

 33) Premium Wifi  

 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 

 
 
 

      314 SKLT  72-3 A 

 

Installation and User Manual 

HELO Roxx Premium

 

REWARD YOURSELF

 

 

Содержание 1107-60-040517

Страница 1: ...A HEATER 1107 60 040517 1107 90 040517 230V 240V 1N 2 230V 3 400V 415V 3N CONTROL PANEL 1601 31 RA 31 Trend 1601 33 RA 33 Premium Wifi 314 SKLT 72 3 A Installation and User Manual HELO Roxx Premium RE...

Страница 2: ...2 12 Heating the sauna 11 2 13 Sauna heater stones 12 2 14 If the sauna heater will not heat up 12 2 15 Door switch 13 2 16 Principle image when RA 33 Premium is used as control panel 14 2 17 BWT tech...

Страница 3: ...these elements may extend the pre heating period even though the sauna room is otherwise well insulated see page 4 section 1 Preparing for sauna heater installation 1 3 Operation of the sauna heater...

Страница 4: ...should be enough room around the sauna heater controls for maintenance purposes Also a doorway can be considered as a maintenance area Only a single sauna heater is allowed per sauna room 2 1 Installa...

Страница 5: ...edges A through the holes in the heater so that the ingoing part is turned upwards The wall mount B is attached to the wall so that the holes where the locking wedges are secured to are upwards The mo...

Страница 6: ...nsor is installed on the sauna room wall no more than 500 mm from the ceiling Once the additional sensor has been connected to the circuit board it is automatically acti vated This means that the temp...

Страница 7: ...bove the heater and in line with the centre line of the heater Do not install the sensor anywhere else 100 490 100 10 280 D 10 40 100 490 100 10 280 D 10 40 Sensor OLET 31 Sensor OLET 31 Sensor OLET 3...

Страница 8: ...uses NOTE Controlling the lights in the sauna with the circuit board is only possible with resistive loads incandescent light bulbs The circuit board relay cannot withstand capacitive loads switched m...

Страница 9: ...rs 3 and 4 of a RJ10 circuit board The recommended cable size is AWG 24 or 26 The maximum length of an AWG 24 cable is 200 m when using a Trend controller The maximum length of an AWG 26 cable is 130...

Страница 10: ...k l mmityksen vuorottelu Alternering med elv rme Signal kontakt Signal contact Contac t du signal Signaalcontact Contacto se al 3 Saunavalo Bastu belysning Saunabeleuchtung Sauna light clairage du sau...

Страница 11: ...THERMOSTAT IS LOCATED IN THE SAME ZONE 2 12 Heating the sauna Before turning the sauna heater on make sure the sauna room is suitable for taking a sauna bath When heated for the first time the sauna h...

Страница 12: ...iled so that they cover the heating elements Do not however pile a large heap of stones on the heating elements For a sufficient amount of stones refer to Table 1 on page 6 Any small stones in the pac...

Страница 13: ...r edge of the door at least 300 mm from the inner corner The switch part is installed on the door frame and the magnet is installed on the door The distance between the switch and the magnet is 18 mm...

Страница 14: ...cuit board OLEA 103 1 Blue 2 White 3 Red 4 Yellow End stop return acknowledgement Adapter circuit board OLEA 103 RJ10 intermedia cable Heater Control panel RA 33 Premium Control panel RA 33 Premium Se...

Страница 15: ...emoved every so often The stones surrounding the tank must be removed during cleaning so that the tank can be lifted more easily When the water is boiling the moisture levels in the sauna remain high...

Отзывы: