![Helmholz WALL IE Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/helmholz/wall-ie/wall-ie_quick-start-manual_2122288023.webp)
Quick Start Guide WALL IE
23
10. Resetting to factory settings
In order to reset WALL IE to the delivery status, the “FCN” button must be activated
while the device is restarted. A restart can be carried out with Power OFF/ON, by
activating the “RST” button or with the “Device reboot” function at the website.
The successful resetting of the parameters and settings is acknowledged during the
boot process by the lit “USR” LED.
11. LED status information
PWR
Off
On
No power supply or device defective.
Device is correctly supplied with voltage.
RDY
On
Device is ready to operate.
ACT
Flashing or on
Data transfer permitted between WAN and LAN.
USR
On
Factory settings reset active.
RJ45 LEDs
Green (Link)
Orange (Act)
Connected.
Data transfer at the port.
12. Button functions
FCN
The WALL IE can be reset to factory settings with the “FCN” button.
To this purpose, the “FCN” button must be kept pressed during the
run-up phase of the WALL IE.
The successful resetting of the parameters and settings is acknow-
ledged during the boot process by the lit “USR” LED.
The “FCN” button can then be released.
RST
The “RST” button triggers an immediate restart of the WALL IE,
in the course of which all saved settings are retained.