TB20, strain gauge weighing module | Edition 1 | 21.12.2018
66
9.3.1
Setting offset/sampling point values
The scale must be unladen to set the offset value! To set the sampling point values, the scale must be
laden with the gaging weights with the value of the sampling point to be set.
Only one load command may be carried out for offset/sampling points (1). No value is transferred when
several load commands are carried out at the same time.
In the right window:
Enter sampling point /offset value (2)
(kg with 2 decimal places without comma)
Activate the offset/sampling point value to be displayed; green display (1).
The field turns yellow.
click in the right window (3). The window turns green following acceptance.
1
2
3
4