Helmholz NETLink Скачать руководство пользователя страница 14

Quick Start Guide NETL ink® Ethernet Gateways

14

8.3 NETL ink® WLAN

Active LED 

Green

 

Non-cyclical flashing indicates WLAN activity. During cycli

-

cal flashing, WLAN partners in range are searched for in 

 

ad hoc mode and infrastructure mode.

DIAG LED 

Orange

 

Diagnoses the WLAN module and only flashes during the 

switch-on process. Otherwise always off in normal opera-

tion (constant light indicates a defect).

Power LED 

Green

 

Is always on and indicates the general readiness for oper-

ation.

Online LED 

Green

 

Only active when the adapter has successfully logged into 

the MPI/ PPI/PROFIBUS.

Data LED 

Green

 

Usually in flashing mode (when a data exchange is taking 

place).

8. LED Description

8.1 NETL ink® PRO Compact

8.2 NETL ink® PRO PoE

Note: 

The red LEDs are only active in the event of a firmware update or when there are 

communication errors!

Power LED 

Blue

 

Is always on and indicates the general readiness for oper-

ation. A flashing Power LED indicates a non-existent/faulty 

TCP/IP connection.

BUS LED

 

Red/green (orange)

 

Flashes orange when the adapter attempts to log in on the 

MPI/PPI/PROFIBUS. When this is successful, the LED switch-

es to a green constant light.

Active LED 

Green

 

Flashes green (when a data exchange is taking place).

Power LED 

Green

 

Is always on and indicates the general readiness for opera-

tion. A flashing Power LED indicates a non-existent TCP/IP 

connection.

Active LED

 

Red/green

 

Only active when the adapter has successfully logged into 

the MPI/ PPI/PROFIBUS.

Data LED 

Red/green

 

Usually in flashing mode (when a data exchange is taking 

place).

Содержание NETLink

Страница 1: ...www helmholz com Version 3 Quick Start Guide NETLink Ethernet Gateways en as of FW 2 60...

Страница 2: ...eparing the NETLink 4 4 IP Address Settings on the PG PC Network Card 6 5 Establishing Access to the Integrated Web Interface 7 6 Integration of an NETLink Adapter into the PG PC Interface of the Engi...

Страница 3: ...cmd OK All NETLink versions with the IP address 192 168 4 49 and the subnet mask 255 255 0 0 are supplied as standard 1 Introduction General note The functions described here relate to 32 and 64 bit W...

Страница 4: ...d that is shown here the IP address range is adjusted to the default value for NETLink 3 2 TCP IP connection Connect the network connection of your PG PC LAN card to the RJ45 LAN socket of the NETLink...

Страница 5: ...nserted ON when the NETLink is plugged in at the start or end of a bus segment If this is not the case the switch must be in the OFF position 3 3 Power over Ethernet connection only NETLink PRO PoE Wh...

Страница 6: ...lt gateway and preferred DNS server Once the settings are applied the LAN connection should be recognized 4 IP Address Settings on the PG PC Network Card Note It is possible that for the following ste...

Страница 7: ...k in the address line URL as follows http 192 168 4 49 As of NETLink firmware version 2 60 the user must define an individual password when calling up the web interface for the first time This must th...

Страница 8: ...adapter can now be reconfigured and stored in the device for example on the configuration page The NETLink can then be accessed in the LAN network via an IP address which is changed here Note If you c...

Страница 9: ...save the parameters in the NETLink WLAN Further details are described in Chapter 7 starting on page 12 5 5 Additional feature Diagnostic function The web interface has a diagnostic function implemente...

Страница 10: ...Windows Control Panel If you re using an old operating system XP SP3 you have to add the interface NETLink S7 NET PRO manually with an intermediate step during the installation Click the New button un...

Страница 11: ...ng and it is possible to work with the Simatic engineering software Note After installation Automatic transmission rate detection is active in the bus settings There are also CPUs or passive participa...

Страница 12: ...tions to other network participants and the internet If several access points are combined the range in a network increases The NETLink WLAN can be used in existing infrastructures 7 WLAN Operating Mo...

Страница 13: ...ations for activation of the ad hoc mode The WLAN network card of the PG PC is to be assigned a fixed IP address match ing the address range of the NETLink WLAN An active proxy server function must be...

Страница 14: ...on 8 1 NETLink PRO Compact 8 2 NETLink PRO PoE Note The red LEDs are only active in the event of a firmware update or when there are communication errors Power LED Blue Is always on and indicates the...

Страница 15: ...freely available diagnostics and update software SHTools you can for example carry out firmware updates yourself In order to ensure the com plete functional scope of your NETLink adapter we recommend...

Страница 16: ...ences as these cannot be fully ruled out The information in this Quick Start Guide is however updated on a regular basis When using your purchased products please make sure to use the latest version o...

Отзывы: