n
Off:
No data recording.
n
Time Triggered:
–
Set a
“Completion Interval”
to define the period for a data
file. After this period each data file is completed. New data
is recorded in a subsequent file.
Choose an interval between 15 min and 1 day from the
drop down list.
–
Set a
“Sample Rate”
to define the period within which
counts are accumulated and new data lines are attached to
the current data file.
Choose a rate between 1 min and 15 min from the drop
down list.
–
Tick the
“Use File Upload”
checkbox for automatic upload
of completed files. File upload has to be activated and
defined in
“File Upload Settings” on page 40
n
GPIO Input Event Triggered:
–
Set a
“Completion Interval”
to define the period for a data
file. After this period each data file is completed. New data
is recorded in a subsequent file.
Choose an interval between 15 min and 1 day from the
drop down list.
–
Tick the Programmable input (
“In0”
or
“In1”
) to choose the
trigger input.
–
Tick
“Inverted”
to invert the logic signal.
–
Tick
“Use File Upload”
checkbox for automatic upload of
completed files. File upload has to be activated and defined
“File Upload Settings” on page 40
.
n
Click the
“Save”
button ( Fig. 43/5) to save all the settings in
the device.
n
Click the
“Reset”
button ( Fig. 43/2) to go back to previous
settings.
n
Click
“Download Data Files”
( Fig. 43/3) for immediate down-
load of all data files from the device to the PC.
n
Click
“Delete all Data Files”
( Fig. 43/4) to delete all data files
from the device (this is useful for maintaining the device
storage space). By default the oldest file is deleted
automatically if memory is full.
The device can automatic send files to an ftp or sftp server.
n
Tick
“File Upload Activated”
checkbox ( Fig. 44/1) to
automatically upload files.
n
Choose one of the
“Protocol Type”
options ( Fig. 44/2).
n
Set up the
“Server Address/Port”
“User
Name”
“User Password”
n
Set up the
“Server Directory”
( Fig. 44/6).
n
Click the
“Save”
button ( Fig. 44/8) to save all the settings in
the device.
n
Click the
“Reset”
button ( Fig. 44/7) to go back to previous
settings.
File Upload Settings
1
2
3
4
5
6
7
8
Fig. 44: File Upload Settings
Configuration
Data Recording
40
09.06.2017
The reproduction, distribution and utilization of this document as well as the communication of its contents to others
without express authorization is prohibited. Offenders will be held liable for the payment of damages.
All rights reserved in the event of the grant of patent, utility model or design.
Содержание APS-R
Страница 64: ......