BMA/BMB-Tool
Technical data of the BMA/BMB Tool
Brake fluid does not fall under the waste oil law and therefore must not be
added to waste oil. Brake fluid must be collected separately from other
substances and taken to a special waste disposal facility.
6.4
Technical data of the BMA/BMB Tool
BMA-Tool
BMB-Tool
Supply voltage
230 V/ 50 Hz
230 V/ 50 Hz
Power cable length
ca. 5 m
ca. 5 m
Brake fluid container size
recommended: 5 l
max. 10 l
max. 20 l
Brake fluid specification
DOT 3 / 4 / 5.1
DOT 3 / 4 / 5.1
Fuse
250 V / 1A T, time-
lag
250 V / 1A T, time-
lag
Ambient temperature
recommended:
10...35 °C
Working range:
5...45 °C
recommended:
10...35 °C
Working range:
5...45 °C
Type of protection
IP 43
IP 43
Pressure generator
Reciprocating pump
230 V/ 50 Hz / 45 W
Reciprocating pump
230 V/ 50 Hz / 45 W
Pressure range
approx. 0-2.8 bar
approx. 0-2.8 bar
Filler hose
approx. 3.5 m long,
with quick-acting
coupling
approx. 3.5 m long,
with quick-acting
coupling
Weight (net)
approx. 8 kg
approx. 12 kg
Dimensions
394 x 245 x 465 mm
(H x W x D)
827 x 370 x 410 mm
(H x W x D)
25
Содержание BMA-Tool
Страница 1: ...HBBMA_BV0001EN0816S0 460 988 04 08 16 User Manual en BMA BMB Tool Original User Manual...
Страница 26: ...Notes BMA BMB Tool Notes 26...
Страница 27: ...BMA BMB Tool Notes Notes 27...