LP Cylinder

Appliance

Tank Ring

Minimum 

0.91 m / 36 in 

LEAK TEST: Apply the solution to the LP gas 

delivery system at points: 

1. Firebowl Valve Coupling 

2. Gas Hose Regulator 

3. Cylinder Valve Coupling

Tank Ring

LEAK TEST: Apply the solution to the LP gas delivery system at points.  

Valve coupling regulator & Cylinder Coupling. 

2. Gas Hose 

Regulator

Heat Sensitive

Hand Wheel

Cylinder

Shut Off

Valve

Check Valve

Nipple with Flow 

Limiting Device

3. Cylinder Valve 

Coupling

!

Caution:

Trip Hazard!

All LP cylinders to be used with this appliance must be: 
a.   Constructed and marked in accordance with the U.S. 

Department of Transportation (DOT) Specifications for LP-
Gas Cylinders
, or the Standard for Cylinders, Spheres and 
Tubes for Transportation of Dangerous Goods
, CAN/CSA 
B339, as applicable. 

b.  Provided with a listed overfilling prevention device.
c.  

Provided with a cylinder connection device compatible with 
the connection for the appliance. 

d.   Only a 9 kg / 20 lb LP gas cylinder is to be used for this 

appliance, approximately 46 cm / 18 in high & 30 cm / 12 in  
diameter.

e.   The use of an approved LP gas cylinder stabilizer, such as the 

one included, must be used when using this appliance in order 
to prevent the LP gas cylinder from tipping over.

CONNECTION:

1.  

Be sure the cylinder valve and appliance valves  
are “off”.

2.  Place full LP gas cylinder on tank stabilizer ring.
3.   Center the nipple in the cylinder valve and hold in place. 
4.   Using the other hand, turn the hand wheel clockwise until there 

is a positive stop. Do not use tools. 

5.   Hand tighten only. When making the connection,  

hold the regulator in a straight line with the cylinder valve, so 
as not to cross thread the connection.

6.   Leak test the connection. See section named “LEAK TEST”.

LEAK TEST:

1.  

DO NOT USE OR PERMIT SOURCES OF IGNITION  
IN THE AREA WHILE DOING THE LEAK TEST. 
THIS INCLUDES SMOKING.

2.  

Leak testing should be done once per year or whenever the 
LP gas cylinder or any other gas system part is taken apart, 
serviced or replaced, whichever is more frequent.

3.   Ensure all gas system coupling joints are tight and properly 

attached.

4.   Prepare a leak testing solution of half liquid detergent  

and half water.

5.   Apply the solution to the LP gas delivery system at points as 

shown in illustration indicated on page 3.

6.  

If parts of the fitting begin to produce bubbles, spray liquid, or 
if you smell liquid propane gas, immediately close the valve on 
the tank.

7.   Wait 5 minutes for any gas to dissipate.
8.   After waiting for 5 minutes, the leak(s) must be stopped by 

tightening the loose joints, if possible, or by replacing the 
faulty parts(s) with the part(s) recommended by the appliance 
manufacturer.

 

 WARNING:

Ensure that the appliance is kept at a minimum distance of  
0.91 m / 36 in from the gas cylinder.

Содержание Outland Firebowl FMPPC2B-875

Страница 1: ...3Z 1A5 USA Canada Toll Free 1 888 514 1663 Tel 1 778 294 0988 Email info outlandliving com Hours of Operation 8 30AM 4 00PM Pacific Time Customer Service in English only 58 000 Btu h Model number FMPPC2B 875 Registered trademark of FMI Brands Inc The OUTLAND flame is a registered trademark of FMI Brands Inc D 875 000 V0 ...

Страница 2: ...or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING For outdoor use only Installation and service must be performed by a qualified installer service agency or the gas supplier CARBON MONOXIDE HAZARD This appliance can produce carbon monoxi...

Страница 3: ...Cylinders used with this unit must have a collar to protect the cylinder valve An approved LP Cylinder stabilizer such as the stabilizer ring included must be used when the appliance is in use Replacement parts and a list of such parts are available from FMI Brands Inc through the contact information provided on the last page of this Manual WARNING Please ensure that all adults and children which ...

Страница 4: ... CONNECTION 1 Be sure the cylinder valve and appliance valves are off 2 Place full LP gas cylinder on tank stabilizer ring 3 Center the nipple in the cylinder valve and hold in place 4 Using the other hand turn the hand wheel clockwise until there is a positive stop Do not use tools 5 Hand tighten only When making the connection hold the regulator in a straight line with the cylinder valve so as n...

Страница 5: ... with either the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural Gas and Propane Installation Code CSA B149 1 or Propane Storage and Handling Code B149 2 or the Standard for Recreational Vehicles ANSI A 119 2 NFPA 1192 and CSA Z240 RV Series Recreational Vehicle Code as applicable PRE IGNITION INSPECTIONS GAS HOSE INSPECTION Clean and inspect the hose before each use of the appliance Attention ...

Страница 6: ...rearrange rocks while unit is ignited STEP 3 The other bag of rocks is included as spares and labelled Spare Rocks These can be stored and used as replacements NOTE Rocks are not to exceed a maximum weight of 4 8 kg or 10 6 lbs STEP 4 Your included Cover is to be used for storage and transportation as shown Never use the cover to extinguish the flame on your Outland Firebowl WARNING Never use the ...

Страница 7: ...f 0 91 m 36 in from the gas cylinder WARNING Ensure that no parts of your body clothing or any other combustible material are above the burner before during and after ignition STEP 6 Your firebowl is equipped with an auto spark ignition Push the knob in and slowly turn counter clockwise to the high position The ignitor will spark and ignite the gas Should the appliance fail to ignite on the first ...

Страница 8: ... WHAT IS AN EXCESS FLOW SAFETY VALVE EFV The EFV is a safety mechanism contained within the gas regulator The purpose of the EFV is to restrict the gas supply if too much gas is flowing too quickly through the gas hose For example this could happen if the gas hose was severed It is normal that your Firebowl EFV trips if you open the propane tank valve too quickly or if you leave the Firebowl gas k...

Страница 9: ...INTENANCE Your Outland Firebowl requires periodic maintenance to keep it in good running order Follow the steps below to ensure your appliance will provide you with the best possible performance STEP 1 Turn cylinder valve to the Closed position STEP 2 Turn appliance valve to the Off position by pushing and turning knob clockwise STEP 3 Allow unit to cool for at least five 5 minutes before relighti...

Страница 10: ...ace any objects other than supplied rocks inside the burner component of the OUTLAND Firebowl Do not add wood or any other materials to the fire It is designed to safely combust gas only Do not connect to a remote gas supply Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control syst...

Страница 11: ...ously a nest or blockage of the burner tube can cause a back flame event damage to your appliance or even extreme operator injuries Mounting Screws and Nuts STEP 4 Remove the gas valve body assembly STEP 5 Use a flashlight to look inside the burner tube Use a long flexible pipe cleaner or long small utensil to clean out any debris or nest material An air tool to blow out the burner is helpful but ...

Страница 12: ... Living product for proof of purchase and warranty at https outlandliving com register products Registration in English only For more warranty information and details please contact FMI Brands Inc at info outlandliving com AUSTRALIA Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compen...

Отзывы: