WES 2000 

– Installation and Hardware Guide 

 

 

5  

 

V 1.2 

NEC 2011 NFPA 70 & 71 
AHJ’s accepted Canada and US 
Labeled CSA model code SPE 1000 

 

Electrical 

Line Supply Voltage 

90-260Vac Single phase 

Typical Power consumption 

100mA 

Max output current consumption 

500 mA 

Max E-Stop Relay current 

15A 

Max E-Stop Relay Voltage 

250Vac 

Radio Transceiver 

GPRS Module 

902-928MHz (frequency hopping 
spread spectrum) 

Housing 

Dimensions 

7.5”H, 7.5”W, 7.5”D (19x19x19cm)  

Certifications 

NEMA Type 1,2,3,4,4X, 12 and 13 
IEC 60529, IP66 
Flammability V-O per UL94 
UV rating (f1) per UL746C stabilized for 
outdoor use 
RoHA Compliant 

Handset/Transmitter 

Specific to handset 

See specific handset documentation 

6

 

Documentation Version 

 

Version 

Date 

Details 

1.0 

April 1, 2015 

Initial Document Release 

1.1 

April 16, 2015 

Minor Updates/Fixes 

1.2 

July 7, 2015 

Legal notice upgrade, and 1000 & 2000 usage for single 
document 

 

Содержание E-Stop Series

Страница 1: ...Helios Global Tech Ltd Helios W E S 1000 2000 Wireless Emergency Stop User Guide E6 Version 1 2...

Страница 2: ...related issue The W E S System carries with it a one year limited warranty at time of purchase Legal Notice CAUTION The E Stop system is not a replacement to the emergency stop button it is an additi...

Страница 3: ...t 2 1 3 Standard Equipment Components 3 1 3 1 W E S Base 3 1 3 2 Signaling transmitter 3 2 Installation 3 3 Operation 3 3 1 Base Unit 3 3 2 Testing 4 4 Troubleshooting 4 5 Specifications 4 5 1 W E S B...

Страница 4: ...top system allowing workers to stop machinery and equipment using a personally carried transmitter The WES system enables a worker or supervisor to open a relay that can be used to immediately disconn...

Страница 5: ...ll Guide 3 Operation 3 1 Base Unit When power is supplied to the base unit the red Alarm LED will be on And the relay contacts will be open In the alarm state the output relay contacts will be open Th...

Страница 6: ...t is still in alarm mode a If the wireless transmitter was used wait another 10 seconds before attempting to reset the system b If there is a handset still currently in alarm or the E Stop button is s...

Страница 7: ...PRS Module 902 928MHz frequency hopping spread spectrum Housing Dimensions 7 5 H 7 5 W 7 5 D 19x19x19cm Certifications NEMA Type 1 2 3 4 4X 12 and 13 IEC 60529 IP66 Flammability V O per UL94 UV rating...

Отзывы: