  Servicing  of  batteries  should  be  performed  or  supervised  by 

personnel knowledgeable of batteries and the required precautions 
should  be  taken.  Keep  unauthorized  personnel  away  from 
batteries. 

  When replacing batteries, replace with the same number of the sealed 

lead-acid batteries. 

  The  socket-outlet  shall  be  installed  near  the  equipment  and  easily 

accessible. 

  With the installation  of  the  UPS, it  should  be  prevented  that  the  sum 

of (UPS and) the connected (load) leakage current exceeds 3.5mA. 

    This pluggable type A equipment with battery installed by the supplier 

is operator installable and may be operated by laymen. 

  Attention!!  Hazardous  through  electric  shock.    Also  with 

disconnection of this unit from the mains, hazardous voltage still may 
be  accessible  through  supply  from  battery.    The  battery  supply 
should  be  therefore  disconnected  in  the  plus  and  minus  pole  at  the 
connectors of the battery when maintenance or service work inside of 
the UPS is necessary. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание BRAVER

Страница 1: ...BRAVER UPS Uninterruptible Power System User s Manual ...

Страница 2: ...sive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit ne...

Страница 3: ...ion of the UPS it should be prevented that the sum of UPS and the connected load leakage current exceeds 3 5mA This pluggable type A equipment with battery installed by the supplier is operator installable and may be operated by laymen Attention Hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery...

Страница 4: ...System Description Front Panel 1 Power Switch LED Indicator 2 LED Indicators AC Mode Green Lighting Battery Mode Yellow Flashing Fault Mode Red Lighting 1 Power switch 2 LCD display ...

Страница 5: ...Back Panel 1 Output receptacles 2 AC Input with AC fuse 3 Modem Phoneline Surge Protection 4 Communication Port ...

Страница 6: ... the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high On the other hand place the UPS unit away from monitor at least 20cm to avoid interference 3 Charging This unit is shipped from the factory wi...

Страница 7: ...ack of the UPS maximum of three devices 5 Modem Phone line Connection Plug incoming internet line into the In socket at the back of the UPS Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS Plug the other end to the modem input socket as shown ...

Страница 8: ...off the UPS please press power switch again 8 DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged Just simply press the power switch to turn on the UPS 9 Green Power Function Braver UPS is equipped with Green Power Function For saving power and protecting battery the method of deep discharging protection is adopted on...

Страница 9: ...Software Installation WinPower XP WinPower XP is a UPS monitoring software which provides user friendly interface to monitor and control your UPS ...

Страница 10: ...oo low 2 Charge battery 8 hours or more 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery Communication lost between UPS and computer 1 Software is not installed well 1 Check the setting of the software 2 Cable is not properly connected 2 Check the RS 232 cable is firmly connected to COM1 COM2 of the computer and...

Страница 11: ...NSFER TIME Typical 4 8ms INDICATOR AC Mode Green light Backup Mode Orange light flashing AUDIBLE ALARM Backup Mode Beeping every 10 seconds Low Battery Beeping every second Overload Beeping every 0 5 seconds Battery Defect Beeping every 2 seconds Fault Continuously Beeping PROTECTION Full Protection Discharge overcharge and overload protection PHYSICAL Dimension mm D x W x H 330 x 100 x 140 mm Net...