68
210
WRONG
RAM
MEM.
Cause:
The algorithm implemented to check the main RAM registers finds wrong
contents: the register is
“
dirty
”
. This alarm inhibits the machine operations.
Troubleshooting
Try to switch the key off and then on again, if the alarm is still present replace the
logic board.
212
W.SET.
TG-EB
XX
Cause:
Supervisor microcontroller has detected that the master microcontroller has
imposed a wrong setpoint for TG or EB output
Troubleshooting:
- Check the matching of the parameters between master and supervisor.
- Ask for the assistance of a Zapi technician.
- If the problem is not solved, replace the logic board.
213
INPUT
MISMAT
CH
Cause:
The supervisor microcontroller records different input values with respect to the
master microcontroller.
Troubleshooting:
- Compare the values read by master and slave through the TESTER function.
- Ask for the assistance to a Zapi technician.
- If the problem is not solved, replace the logic board.
227
OUT
MISMAT
CH XX
Cause:
This is a safety related test. Supervisor
μ
C has detected that master
μ
C is
driving traction motor in a wrong way (not corresponding to the operator request).
Troubleshooting:
- Checks the matching of the parameters between Master and Supervisor.
- Ask for assistance to a Zapi technician.
- If the problem is not solved, replace the logic board.
229
NO CAN
WR
MSG.XX
Cause:
CANbus communication does not work properly. The hexadecimal value
“
XX
”
identifies the faulty node.
Troubleshooting
Verify the CANbus network (external issue). Replace the logic board (internal
issue).
230
SOFTWA
RE
ERROR
Cause:The software of the slave microcontroller is wrong,ask help to the inveter
manufacturer
235
CTRAP
THRESH
OLD
Cause
This alarm occurs when a mismatch is detected between the setpoint for the
overcurrent detection circuit (dependent on parameter DUTY PWM CTRAP) and
the feedback of the actual threshold value.
Troubleshooting
The failure lies in the controller hardware. Replace the logic board.
Содержание G3 Series
Страница 1: ......
Страница 4: ...1 I Main specifications of forklift trucks 1 External view of the truck P1 R G F C D ...
Страница 29: ...26 Figure 4 1 Principle diagram of electric system CPD40 50 GB3Li ...
Страница 30: ...27 Figure 4 2 Principle diagram of electric system CPD40 50 GB2Li ...
Страница 109: ...106 5 Connect the battery 6 Close the side door ...
Страница 110: ......