* Uses CR1632 or equivalent battery

Follow Instructions for Use. This document provides important product operation and 

safety information regarding this thermometer. Please read this document thoroughly 

before using the device and keep for future reference.

Please read these instructions carefully to ensure accurate temperature measurements and safe operation. When used properly, this product will give you years of 

accurate, dependable service.

IMPORTANT SAFETY INFORMATION

•  High, prolonged fever requires medical attention especially for young children. Please contact your physician.

•  Do not allow children to take their temperatures unattended.

•  Do not allow children to walk or run during temperature taking.

•  The thermometer is only suitable for the measurement of body temperature. The use of this thermometer is not intended as a substitute for 

  consultation with your doctor.

•  The thermometer is initially calibrated at the time of manufacture. If this thermometer is used according to the use instructions, the 

  accuracy of measurements will not be affected.

•  Do not use the device if you think it is damaged or if anything appears unusual.

•  Do not store the unit under direct sunlight, at a high temperature, or in high humidity or dust. Performance may be degraded.

•  Using the unit in the immediate vicinity of mobile phones, microwave appliances or other devices with strong electromagnetic fields may  

  result in impaired functioning.

•  Do not use this device close to strong electromagnetic fields, such as mobile telephones or radio installations. Keep a distance from such  

  devices when using this unit.

TEMPERATURE READINGS

Temperature readings vary from person to person. Although there is no one “normal” temperature reading, a temperature, taken orally, 

ranging between 37.4°C / 99.4°F and 35.8°C / 96.4°F is considered normal. A rectal temperature is generally 0.5°C / 1°F higher and an underarm 

(axillary) temperature will be 0.5°C / 1°F lower.

The best method to determine your own normal temperature is to use the thermometer when you are feeling well. Record your reading twice 

a day (early morning and late afternoon). Take the average of the two temperatures. This is considered your normal 

body temperature. Any variation from it may indicate illness and you should consult your physician.

BEFORE USE

Your Vicks Fever InSight

®

 Thermometer is a 3-in-1 thermometer for oral, rectal, or underarm use. Whichever method 

is used, it is recommended that for 15 minutes prior to use, you avoid eating or drinking, exercising, taking showers or 

baths or smoking.

OPERATING YOUR VICKS FEVER INSIGHT

®

 THERMOMETER

1. TURNING THE THERMOMETER ON

  •   Turn thermometer on by pressing the On/Off button 

(Fig. 1)

  •   A beep signal will sound and the display will flash Red/Yellow/Green for 1 second. 

  •   Wait for the thermometer to get ready 

        – The display will perform a self-test 

(Fig. 2)

        – The display will show last measurement for 2 seconds

 (Fig. 3)

        – After about 5 seconds, the display will show it’s ready 

(Fig. 4)

.

2. SELECTING WHERE TO TAKE THE TEMPERATURE

  Oral Use

 • 

It is important to place the tip of the thermometer well under the tongue to get a good, accurate 

reading. 

(Fig. 5)

 

Place sensor tip in areas marked with “

4

”. 

Keep mouth closed and sit still to help ensure an accurate measurement.

  •  When peak temperature is reached (usually within 12 seconds), 5 beep signals will sound 

and the “°C/°F” sign will stop flashing. The temperature measurement is now ready to read and  

will not change when the thermometer is removed.

  •  Wash the thermometer as recommended.

  Under-the-arm (Axillary) Use

  This method can be used for babies and young children.

  •  Wipe the underarm with a towel.

  •  Place the probe tip under the arm so the tip is touching the skin and position the arm next to the body 

(Fig. 6)

.

    With a young child, it may be helpful to hug the child to keep their arm next to their body. 

    This ensures that the room air does not affect the reading.

  •  When peak temperature is reached (usually within 11 seconds but sometimes longer for this 

method), 5 beep signals will sound and the “°C/°F” sign will stop flashing. The temperature 

measurement is now ready to read and will not change when the thermometer is removed.

  

Note: This method produces a temperature reading 0.5°C / 1°F lower than if the temperature were 

taken orally.

  •  Wash the thermometer as recommended.

  Rectal Use

  Commonly used for babies, young children, or when it is difficult to take an oral or underarm temperature.

 • Cover the thermometer’s tip with a probe cover and lubricate with a water-soluble jelly for easier 

insertion. 

DO NOT

 use petroleum jelly. Read the label of the lubricant to be sure you are using the right kind.

  •  Lay the individual on his/her side. If the individual is an infant, the proper position for a baby is to lay on 

its stomach with legs hanging down, either across your knees or at the edge of a bed or changing table. 

This positions the infant’s rectum for safe and easy insertion of the thermometer.

  •  Gently insert the tip of the thermometer NO MORE THAN 1/2 inch into the rectum. If you detect 

resistance, stop. Hold the thermometer in place during measurement.

  •  When the peak temperature is reached 5 beep signals will sound and the “°F” sign will stop flashing. The 

temperature is now ready to read and will not change when the thermometer is removed.

    Note: This method produces a temperature 1° higher than a temperature taken orally.

  •  Dispose of used probe cover and wash the thermometer as recommended.

3. READING THE MEASUREMENT: FEVER INSIGHT

®

 FEATURE

The Vicks Fever InSight

®

 Thermometer comes with the patented “Fever InSight

®

” feature which offers a color indicator with the temperature 

reading. This feature will help you explain to your child the meaning of temperature. It also helps by distracting your child from possible fear 

associated with temperature taking, especially with young children.

 •  For readings between 35.8-37.4°C / 96.4-99.4°F, the screen will display green as the backlight color indicating the temperature is within the 

“normal” range.

 • For readings between 37.5-38.5°C / 99.5-101.3°F, the screen will display yellow as the backlight color indicating a slight elevation in temperature.

  •  For readings 38.6°C / 101.4°F and above, the screen will display red as the backlight color indicating possible fever. 

  The Fever InSight

®

 feature continues for about 5 seconds.

4. TURNING THE UNIT OFF

  Turn the thermometer off by pressing the On/Off button. If you forget to turn it off, the thermometer will automatically turn off after    

  approximately 1 1/2 minutes.

CHANGING TEMPERATURE SCALE FROM °C TO °F OR °F TO °C

When the power is off, press and hold the On/Off button for 4 seconds, when the “M” symbol disappears, release the button and press the 

button to switch from °C to °F or °F to °C . After 3 seconds idle, the thermometer enters into the ready-for-measurement mode.

CLEANING INSTRUCTIONS

•  Clean the thermometer by washing it with soap and warm water or rubbing alcohol (70% isopropyl alcohol).

•  Wipe dry with soft cloth.

•  DO NOT BOIL OR WASH IN DISHWASHER. This will cause the thermometer to no longer function and will void the warranty.

•  Do not wash with any thinner or chemical solvent.

SPECIFICATION

Type:  

Digital Thermometer (Predictive)

Battery Lifetime:  

Approx. 2000 measurements.

Accuracy in water bath:  ±0.1°C between 35.5°C / 42.0°C at room temperature of 21.6°C  

 

±0.2°F between 96.0°F-107.6°F at room temperature of 71°F

Temperature Range: 

32.0-43°C. If less than 32.0°C “Lo” is displayed. If more than 43°C “Hi” is displayed. 

 

89.6°F-109.4°F. If less than 89.6°F “Lo” is displayed. If more than 109.4°F “Hi” is displayed.

Operating Temperature:  +10°C to +40°C (50°F-104°F), 15% to 95% RH

Storage Temperature: 

-25°C to +60°C (-13°F-140°F), 15% to 95% RH

 

If the device is not used within specified temperature and humidity ranges the technical accuracy of the 

measurement cannot be guaranteed.

Beeper: 

The thermometer will beep for approximately 8 seconds when peak temperature is reached.  

For temperatures over 38.3°C/101.3°F, the audible Fever Alert will sound 5 times.

Error Messages: 

The display will read “Err” when a malfunction occurs and the thermometer will power off.

Expected Service Life:  5 years

 

Device standard: • EN 12470-3         • ASTM E1112        • ISO 80601-2-56        • IEC 60601-1        • IEC 60601-1-2(EMC)        • IEC 60601-1-11

• IP67: Dust tight, no ingress of dust; 2 to 8 hours. Protection against the effects of immersion in water between 15 cm and 1 m for 30 minutes.

CHANGING THE BATTERIES

The Vicks Fever InSight

®

 Thermometer features a long life battery. When the “   ” appears and flashes in the center top of the display, the 

battery needs replacing.

1. Using a coin, unlock the battery cover and carefully remove the battery with a non-metallic instrument.

2. Replace the battery with a 3V, CR1632 lithium type or equivalent. Insert the new battery with the positive (+) side facing the battery cover.

3. Carefully put the battery cover back in place and, using a coin, tighten the cover.

4. Properly dispose of the old battery. Keep out of reach of young children, elderly and pets. Ensure the battery door is completely secure after 

replacing the battery.

WARNING

 

- KEEP BATTERIES OUT OF REACH OF CHILDREN. Some parts are small enough to be swallowed. If you suspect a button battery has been ingested, call 

Poisons Information immediately on 13 11 26. Ensure battery compartment is correctly secured.

LIFETIME WARRANTY

This product has been produced with the greatest care for normal, household use. Following directions carefully will ensure dependable operation. 

If for any reason (other than misuse or normal battery operation) you are dissatisfied with your Vicks Fever InSight

®

 Thermometer, we will repair or 

replace it, at our option, at no charge during the lifetime warranty period. Modification to the product by the consumer is not authorised and voids the 

warranty. 

If the thermometer does not function properly, first check the battery. Replace if necessary. Batteries and packaging are excluded from the warranty. 

If you experience unsatisfactory operation, please contact Felton Grimwade & Bosisto’s. If repair is required under the warranty period, the product 

should be returned with proof of purchase to Felton Grimwade & Bosisto’s service centre. 

The purchaser assumes responsibility for the proper care and use of the product in accordance with the printed operating manual. The purchaser or 

user must make his or her judgment as to when to use the product and the length of use. Keep the operation manual available as it is your guide to 

safe, efficient operation.

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major 

failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the 

goods fail to be of acceptable quality and the failure does not amount to a major failure. 

Probe Tip

On/Off Button

Large Display with 

Fever InSight® backlight

Battery 

Compartment

(on back side)

Important: Before first use, 

remove label from the display.

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig.5

Fig.6

P/N: A005506R0 

    DATE: 02NOV20

Distributed by: Felton Grimwade & Bosisto’s Pty. Ltd.

61-81 Clarinda Road (Po Box 74), Oakleigh South, 

Victoria 3167, Australia

Free call: 1800 655 841          E-mail: [email protected]

Website: www.fgb.com.au

Australian sponsor: RQSolutions Pty Ltd.  

Suite 1A Level 2, 802 Pacific Highway, Gordon NSW 2072

Microlife Intellectual Property GMBH 

55 Northern BLVD., Suite 200 Great Neck, NY 11021

Made and printed in China          www.kaz.com/vicks

This thermometer should be used by adults only. Do not leave 

the device unattended with children under the age of 12.

The stipulations of EU-Directive 93/42/EEC for  

Medical Devices Class IIa have been fulfilled. 

BF Type applied part

Batteries and electronic instruments must be disposed of in accordance 

with the locally applicable regulations, not with domestic waste.

This product is manufactured by Microlife Intellectual Property GMBH for Helen of Troy 

Health and Home, under license from The Procter & Gamble Company. 
Certain trademarks used under license from The Procter & Gamble Company or its affiliates.
Fever Insight

®

 is a registered trademark owned by Helen of Troy Limited and/or its affiliates. 

© 2021 All rights reserved.

Fever InSight

®

 Thermometer

Model V916C-AUSV1

Отзывы: