4. Before Installation/Commissioning
The product must only be used outside its packaging.
Take the product carefully out of the packaging.
Make sure that the product has not been damaged during transport before putting the light into operation.
You must not use the product if there is any damage to electrical parts. Repairs may only be carried out
by a qualified electrician.
Keep packaging materials away from children and pets. Asphyxiation hazard!
5. Installation/Commissioning
This product can only be installed by a qualified electrician.
The connection lines in the building must be disconnected before installation and secured against being
switched back on. For this, trip the corresponding fuse switch in the building installation.
Make sure that the surface is suitable for permanently and reliably taking the weight of the product.
Now connect the building installation's connection lines to the screw terminals on the light. The brown (or
black) cable is generally the phase conductor - connect this to the terminal marked with "L". The blue
conductor must be connected to the terminal marked with "N".
Do not bend the cables; make sure that the cables are not subject to tension or torsional forces. Protect
all cables and insulation against possible damages.
Check proper connection once again.
Switch the building installation's fuse switch back on.
Settings ON/OFF/PIR (control switches)
6. Faulty Function
Light does not switch on
Check the connected lines
Sensor set correctly?
7. Technical Data
Article
Port
Motion sensor
Protec-
tion
Type
Protec-
tion
Class
42197
230 V ~ AC,
50 ~ 60 Hz
max. 1200 W, max. 300 W ESL, LED
Lux: approx. 3-2000
Time setting: approx.10 sec. - 7
min
Detection radius: approx. 160°
Detection distance: approx. max.
9 m
Installation height: approx. 1-1.8
m
IP20
II