HeiTel TDT C1500 Скачать руководство пользователя страница 11

TDT C1500 

 

Router Configuration 

 

 

Assignment

 

for

 

the

 

PPP

 

Interface

 

created

 

takes

 

place

 

under

 

Static Connections

.

 

Click

 

Add

 

to

 

add

 

the

 

preselected

 

interface

 

ppp0

.

 

Accept

 

this

 

setting

 

by

 

clicking

 

Apply

.

 

 

Under

 

Connections

 

in

 

the

 

Connection-Manager

,

 

the

 

previously

 

created

 

connection

 

must

 

now

 

be

 

activated.

 

Click

 

Add Connection

 

to

 

open

 

a

 

mask

 

on

 

which

 

to

 

create

 

a

 

new

 

connection.

 

Under

 

Use Interface

 

the

 

ppp0

 

interface

 

created

 

is

 

selected

 

by

 

default.

 

All

 

other

 

settings

 

can

 

be

 

accepted

 

as

 

they

 

are.

 

Create

 

the

 

entry

 

by

 

clicking

 

Create

.

 

 

 

 

Click

 

Return to Connection-Manager

 

to

 

return

 

to

 

the

 

overview

 

where

 

the

 

connection

 

you

 

just

 

created

 

is

 

now

 

displayed.

 

Under

 

Activate Connection-Manager

 

select

 

Yes

 

and

 

accept

 

the

 

settings

 

by

 

clicking

 

Apply Changes

.

 

 

To

 

check

 

the

 

PPP

 

connection

 

to

 

the

 

mobile

 

network

 

provider,

 

use

 

the

 

function

 

Active PPP 

Connections

 

(see

 

Networking/PPP Functions/Active PPP Connections

).

 

Technical Production Information 

© HeiTel Digital Video GmbH 2010

 11/18

 

Содержание TDT C1500

Страница 1: ...r camdisc svr cam4mobile CamDisc HNVR http www heitel com en service upgrades firmware camdisc hnvr Download CamControl LITE Demo Version http www heitel com en service downloads CamControl LITE Download CamControl PRO Demo Version http www heitel com en service downloads CamControl PRO Contents 1 Introduction 2 2 Requirements 2 3 Router Preparation 3 3 1 Insert data card 3 3 2 Power supply 3 3 3 ...

Страница 2: ...12 V DC power supply unit for HeiTel transmitters 8 30 V DC power supply for Cam4mobile CamControl LITE or CamControl PRO software of version 3 82 or higher as receiver and archive access software TDT C1500 router series 12 V DC power supply for TDT C1500 router o Nominal voltage 12 V operating voltage range 7 18 V DC o Rated current 1 2 A 3G UMTS antenna A SIM card from the mobile network operato...

Страница 3: ...not PIN protected 3 2 Power supply Connect to the power supply in accordance with manufacturer instructions 3 3 Network connection The C1500 router has two network interfaces WAN and LAN For router configuration with a PC or Notebook or to connect a HeiTel video system use only the LAN network interface Technical Production Information HeiTel Digital Video GmbH 2010 3 18 ...

Страница 4: ...Username tdt Password tdt To configure the router proceed as follows 4 1 Creating a connection to the router Access to the Web interface is via SSL encrypted transfer Web browsers usually protest that this certificate is not trustworthy and classify the Web interface as unsafe To gain access depending on the browser an exception must be created or loading continued despite the recommendation After...

Страница 5: ...ction is configurable here For a mobile network connection the area PPP Functions is used The log files and status displays under Diagnose can be used to locate errors Configuration changes to the router are temporary following a restart or power failure default or previously stored configurations are active To create a permanent configuration after entering changes under Permanent Save the functi...

Страница 6: ...ions and for the hardware GSM Modem State 4 3 2 Step by step configuration PPP Interfaces can be configured in the Networking area under the function PPP Functions A PPP Interface contains the entire configuration for connection to the provider User name and password are stored the connection type e g GRPS or UMTS selected or those actions configured that are accessed following establishment of th...

Страница 7: ...y No PPP interfaces configured Click Create a new PPP interface to create a new PPP Interface Accept the default setting PPP0 and select the option UMTS GPRS Click Create to open the editing mask Adjust the parameter for the SIM card used SIM card SIM 2 Technical Production Information HeiTel Digital Video GmbH 2010 7 18 ...

Страница 8: ...ou now need to enter the PPP access data for the relevant provider in the editing mask Example Vodafone Germany APN web vodafone de Username Password All other settings are to be entered as shown on the screenshot Once you have made these settings complete the procedure by pressing Save Technical Production Information HeiTel Digital Video GmbH 2010 8 18 ...

Страница 9: ...ged to Yes All other entries are standard settings After you click Save the previous page listing the PPP Interfaces is displayed and ppp0 must be opened again for editing Select here the Advanced Settings button Here too close this editing mask by pressing Save Technical Production Information HeiTel Digital Video GmbH 2010 9 18 ...

Страница 10: ...onnection Manager Functions is required This is responsible for dynamic connection i e connection when required or static connection i e connection as soon as the router is started Click the Connection Manager Functions symbol to access the relevant function Click on the Static Connections symbol to access the relevant function Technical Production Information HeiTel Digital Video GmbH 2010 10 18 ...

Страница 11: ...e Interface the ppp0 interface created is selected by default All other settings can be accepted as they are Create the entry by clicking Create Click Return to Connection Manager to return to the overview where the connection you just created is now displayed Under Activate Connection Manager select Yes and accept the settings by clicking Apply Changes To check the PPP connection to the mobile ne...

Страница 12: ... If a connection was created under Active PPP Connections the current values for Type connection type Local IP WAN IP address of the router Remote IP provider IP address State status and Uptime operating time are displayed Technical Production Information HeiTel Digital Video GmbH 2010 12 18 ...

Страница 13: ... with the mobile network connection that signal strength is sufficient and that registration with the provider was successful For analyses system information and the router logs are available If a connection has been created successfully data on the registered network is given here The Signal Quality bar indicates the signal strength of the mobile network Click Refresh to update the display Techni...

Страница 14: ...al additional antenna If not intermittent connectivity or considerably slower transfer speeds could result The LED indicators at the front provide information on the current operating status see TDT C1500 series device manual Technical Production Information HeiTel Digital Video GmbH 2010 14 18 ...

Страница 15: ...f the LAN interface The LAN interface is administered in the router as eth0 Under Networking you will find the option Network Configuration Click Network Interfaces to view a list of all interfaces Technical Production Information HeiTel Digital Video GmbH 2010 15 18 ...

Страница 16: ...r Interfaces Activated at Boot Time IP address network mask and MTU can be adapted to the existing network The IP address adapted here is the gateway address for other devices in the network of the router The DHCP service active on the router can generate collisions in a network with other DHCP services Further documentation and configuration options including tips can be found in the manual or on...

Страница 17: ...f necessary contact your mobile network provider to obtain the necessary information Example Vodafone Germany DNS1 139 7 30 125 DNS2 139 7 30 126 If you wish to use the DHCP function of the C1500 router and the latter was configured correctly instead of the connection settings given above you can also activate the Obtain an IP address automatically DHCP function and if necessary also the Obtain a ...

Страница 18: ...an active connection to the receiving PC To use HTconnect under Connections HTconnect the fixed IP address of the receiving PC must be entered Any port releases on the receiving side must be taken into account here More information on HTconnect http www heitel com en products heitel techniques htconnect Technical product information on HTconnect http www heitel com upload downloads en 11 technical...

Отзывы: