8. Regulating Linkage
HELENOS III
16
7.3. Specification
StG 16 - *
StG 30 - *
StG 40 - *
Effective rotation at the
output shaft
42 °
42 °
42 °
Max. torque at the governor
output shaft (direction stop)
approx. 15 Nm
approx. 28 Nm
approx. 44 Nm
Holding moment in
current limitation
approx. 7.5 Nm
approx. 14 Nm
approx. 22 Nm
Response time 0-100 %
without load
approx. 120 ms
approx. 170 ms
approx. 190 ms
Current consumption of
whole governor:
in steady state condition
approx. 1 A
approx. 1 A
approx. 1.5 A
on change of load
approx. 3 - 4 A
approx. 3 - 4 A
approx. 4 - 5 A
max. current
approx. 4.5 A
approx. 4.5 A
approx. 6 A
in current limitation
approx. 2.5 A
approx. 2.5 A
approx. 3 A
Storage temperature
-55°C to +110°C - 55°C to +110°C -55°C to +110°C
Ambient temperature
in operation
-25°C to +90°C
-25°C to +90°C
-25°C to +90°C
Ambient temperature
special version
-40°C to +90°C
-40°C to +90°C
-40°C to +90°C
Humitity
up to 100 %
up to 100 %
up to 100 %
Protection grade:
IP 44
IP 44
IP 44
Weight without base
approx. 12.3 kg
approx. 12.3 kg
approx. 12.3 kg
Weight of base
approx. 1.3 kg
approx. 1.3 kg
approx. 1.3 kg
Содержание DG 162-02
Страница 2: ......
Страница 36: ...9 Electric Connection Helenos III 28 Fig 21 Connections with Terminal Strip IP 00 for Vehicle Operation...
Страница 42: ...9 Electric Connection Helenos III 34 Fig 27 Connections with Terminal Strip IP 00 for Marine Twin Operation...
Страница 44: ...9 Electric Connection Helenos III 36 Fig 29 Connections with Terminal Strip IP 00 for Marine Single Operation...
Страница 49: ...12 Ordering Specifications Helenos III 41 12 2 Harness Fig 30 Harness with Cable Numbers...
Страница 50: ...12 Ordering Specifications 42 Helenos III 12 3 Plug Connections Fig 31 Plugs with Designation...