NOTE

1. Perform the SENSITIVITY TEST as requested.

2.  Clean  the  detector  surface  with  soft  bristled  brush  every  6 

months  t

.  Remember  to  cut 

off the power source  before cleaning.

3.  If    the  detector  is  not  used  for  a  long  time,  remove  the 

detector, take out the battery from the cabinet and store it in a 

cool and dry place.

4. The detector can reduce the happening rate of disasters.  But  

it  can  not  guarantee  a  hundred  percent  safe.  For  safety 

consideration,  pls  use  the  detector  properly  and  heighten 

vigilance  and  safety  consciousness  to  take  preventive 

measures. 

o  assure  the  detecting  sensitivity

operation.

ls contact 

with  the  dealer  in  time.  Do  not  attempt  to  remove  and  repair 

the detector personally to prevent  incidents.

If  the  buzzer  gives  out  2  Di  sounds  every  40  seconds  along 

with  the  alarm  indicator  flashing  twice,  the  infrared 

photoelectronic sensor should have a malfunction. P

OPERATING INSTRUCTION

1. Usage

1)  Inserting  the  ready  battery  into  the  battery  cabinet  and 

keeping  the battery power supply, 

2) Connecting the AC power wires (for AC TYPE), the detector 

enters  into  normal  working  status.  The  indicator  flashes  once 

per 45 seconds.

2. Sensitivity Test

The  detector  should  be  tested  periodically  to  assure  normal 

operation.  Once  per  month  is  recommended.  Press  and  hold   

the  TEST  &  HUSH  BUTTON  for  more  than  1s  to  make  the 

detector enter into testing status. If the alarm indicator  flashes 

rapidly and the buzzer gives out alarm sound, then 

3. Alarm & Hush Function

When  smoke  density  in  surroundings  reaches  the  alarm 

threshold  of  the  detector,  the    buzzer    gives  out  alarm  sound 

and  the  alarm  indicator  flashes  rapidly. At  this  time,  pressing 

the TEST & HUSH BUTTON will make the detector enter into 

mute  status  that  lasts  for  10  minutes.    During  this  period,  the 

indicator flashes once per 10s and if the density is still higher 

than  the  threshold,  the  TEST  &  HUSH  BUTTON  is 

nonfunctional.  When  the  smoke  density  goes  below  the 

threshold, pressing the TEST & HUSH BUTTON will activate 

the detector to perform testing operation. A

he detector recovers automatically to normal working status .

4. Interconnection Alarm

Under  interconnection  condition,  if  a  detector  only  gives  out 

alarm  sound  and  its  alarm  indicator  does  not  flash,    it  means 

alarm occurs among the other interconnected detectors.  At this 

time,  press  the TEST  &  HUSH  BUTTON  to  hush  the  detector 

alarm sound and find the detector in alarm status. Meanwhile, 

check  the  surroundings  of  each  detector  to  prevent  potential 

losses.

 the detector 

works properly.

fter the 10 minutes, 

t

5

Malfunction Check

When  the  detector  buzzer  gives  out  a  Di  sound  every  40 

seconds  along  with  the  alarm  indicator  flashing  once,  the 

battery  voltage  should  become  lower  than  the  detector’s 

normal operating voltage. At this time, replace the battery with

a  new  one.  Otherwise,  it  will  influence  the  detector’  normal

User Manual for Photoelectronic Smoke Detector 

2

M207-1EVer1.0