background image

FEATURES

● 

Wire

 

Interconnection Alarm

● 

Hush Button

● 

Malfunction

 

Auto-Check 

● 

Auto

-

Reset

 

After

 

Trigger

● 

Infrared Photoelectronic Sensor

 

● 

Sound & Flash

 

Alarm / LED Indicating

 

Alarm

● 

SMT

 

Manufacture

 

Technology,

 

Reliable

 

Stability

● 

Dust-proof, Moth-proof, Anti White Light Interference

● 

Adopts

 

MCU Auto-Processing Technology

 

Anti-RF Interference (20V/m-1GHz)

 

PRODUCT INTRODUCTION

This

 

product  is  a  photoelectronic  smoke  detector,  hereinafter 

called  detector.  With    a  unique  structure  design  and    an 

intelligent  MCU  to    process  photoelectronic  signals,  it  is 

p r o v i d e d  w i t h  d u s t - p r o o f ,  m o t h p r o o f    a n d  a n t i - l i g h t 

interference etc. functions, ensuring the detector stability from 

design  basis  and  suitable  for  all  kinds  of  installation 

environments.    It  reacts  very  quick  to  visible  smoke  released 

by smoldering fire and flaming fire, and suitable for fire alarm 

in houses, factories, shopping malls, hotels, restaurants, office 

buildings,  teaching  buildings,  banks,  libraries,  warehouses, 

etc..

INSTALLATION

1. Avoid  installations  in  places  with  stagnating  smoke,  heavy 

dust, heavy water mist, heavy oil mist, great humidity (

 

and high wind speed ( >5m/s).

2

.

Insert  the  ready  battery  into  the  battery  cabinet.  Choose  a 

proper  position.  Normally,  the  center  of  the  detection  area 

ceiling is recommended. Fix the detector base into the chosen 

position and connect the wires if the detector is an AC TYPE. 

Then  put  the  detector  into  the  base  and  twist  to  fasten  it.    Be 

sure  it is fastened tightly.

 >95%)

User Manual for Photoelectronic Smoke Detector 

TECHNICAL PARAMETERS

Operating

 

voltage: 

 

(

F22 carbon battery, DC TYPE)

 

AC220V /110V with 9V backup battery (AC TYPE)

Alarm

 

indication: LED flashes

 

in

 

Red

Alarm

 

sound:

85dB/3m

Operating

 

temperature:  -10

℃ 

~

 

+50

Humidity:  

95

RH

Dimension:

Φ

 

Execution

 

standard: GB4715-2005, EN14604, UL217 

Detecting

 

area:  80

㎡ 

at 6

-

12m

 

installation

 

height; 

                              60

㎡ 

at

 

installation

 

height

 

<6m.  

9V battery 6

Static

 

current: <10uA      

Alarm

 

current: <35mA

Battery life: carbon battery for about 1year

Power indication: Green LED constant ON (AC TYPE)

128*38mm

OPERATING PRINCIPLE

This detector adopts the principle of smoke particles reflecting 

infrared  lights.

 

The  main  circuit    includes  a  MCU  processing 

part,  an  infrared  emission  part  and  an  infrared  reception  part. 

The  emission  and  reception  diodes  are  placed  in  the  optical 

maze  chamber  which  can  shield  the  interference  of  outside 

stray  lights,  but  will  not  influence  smoke  entering  into  the 

detector. On smokeless conditions, the received infrared lights 

are very weak. When smoke entering, due to scattering effects , 

the  received  light  signals  increase.  When  smoke  density 

accumulates  up  and  reach  the  alarm  threshold  of  the  MCU,   

PRODUCT

 

PROFILE

Note: 

1) If not equipped with the wire assembly, the detector is a DC TYPE 

and  does not have  the interconnection function. 

2)  If  not  equipped  with  the  yellow  interconnection  wire  in  the  wire 

assembly, the detector does not have the interconnection function.

the  detector  will  blink  its  alarm    indicator,  give  out    strident 

alarm  sound

 

and

 

send  out  alarm  signal  to  the  other 

interconnected detectors.

1

BUZZER

POWER

 

INDICATOR

TEST & HUSH BUTTON 

ALARM INDICATOR

WIRE ASSEMBLY

M207-1EVer1.0

INTERCONNECTION WIRE (YELLOW)

AC POWER CATHODE WIRE (BLACK)

AC POWER ANODE WIRE (WHITE)

Отзывы: