UNIT INTRODUCTION

This unit is a small packaged gas heat/electric cooling system that
can utilize

the comfort of gas heating packaged along with

efficient electric air conditioning. This unit uses R--410A, the
environmentally balanced refrigerant for cooling.

Starting or Shutting Off Unit

NOTE

: Your combination heating/cooling unit is equipped with

an automatic direct spark ignition and power combustion blower.

To start unit gas heat:

Refer to Fig. 2 for location of unit front access panel. Refer to Fig.

3 for location of gas valve. Refer to Fig. 4 while proceeding with

the following steps.

1. Set the temperature selector on room thermostat to the low-

est temperature setting and set system switch to HEAT.

2. Close the external manual gas shutoff valve.
3. Turn off the electrical supply to the unit.
4. Remove the control access panel with a 5/16--in. nut driver.

(See Fig. 2.)

Compressor

Access

Panel

Filter Access Panel

For Accessory Filter Rack

Blower

Access

Panel

Control

Access

Panel

A09213

Fig. 2 -- Unit Access Panel

5. Move the selector switch on the internal gas valve to the

OFF position and wait 5 minutes.

6. Move the selector switch on the internal gas valve to the ON

position.

7. Replace the control access panel.
8. Turn on the electrical supply to unit.
9. Open the external manual gas shutoff valve.

10. Set the temperature selector on room thermostat slightly

above room temperature to start unit. The induced--draft
combustion air fan will start. Main gas valve will open and

main burners should ignite within 5 seconds. If the burner
does not light within 5 seconds, the ignition module will go
into a Retry Mode after a period of approximately 22

seconds (following the 5--second ignition period). If the
burners do not light within 15 minutes of the initial call for

heat, there is a lockout.

11. Set the temperature selector on room thermostat to desired

setting.

FIRE AND EXPLOSION HAZARD

Failure to follow this warning could result in personal

injury, death, and/or property damage.
1. If the main burners fail to light, or the blower fails to

start, shut down gas heating section and call your dealer for

service.

2. Never attempt to manually light the main burners on unit

with a match, lighter, or any other flame. If the electric

sparking device fails to light the main burners, refer to the

following shutdown procedures, then call your dealer as

soon as possible.

!

WARNING

Burners

Gas Valve

Flue Hood

A14448

Fig. 3 -- Gas Heating/Electric Cooling Unit with Access Panel

Removed

T

o shut off unit gas heat:

FIRE,

EXPLOSION,

ELECTRICAL

SHOCK

HAZARD

Failure to follow this warning could result in personal

injury, death, and/or property damage.
Do not turn off the electrical power to unit without first

turning off the gas supply.

!

WARNING

NOTE

: If the unit is being shut down because of a malfunction,

call your dealer as soon as possible.
Should overheating occur or the gas supply fail to shut off, shut off
the external manual gas valve to the unit before shutting off the

electrical supply. Do not use this unit if any part has been under
water. Immediately call a qualified service technician to inspect the

unit and to replace any part of the control system and any gas

control which has been under water.
Refer to Fig. 5 while proceeding with the following steps.

1. Set the temperature selector on room thermostat to lowest

temperature setting and set system SWITCH to OFF.

2. Close the external manual shutoff valve.
3. Turn off the electrical power supply to the unit.
4. Remove the control access panel. (See Fig. 2.)
5. Move the selector switch on the internal gas valve to the

OFF position.

6. Replace the control access panel.

Содержание PGD4

Страница 1: ..._ _____________________________________________ _____________________________________________ INSTALLATION INFORMATION Date Installed________________________________ DEALERSHIP CONTACT INFORMATION Company Name_______________________________ Address______________________________________ _____________________________________________ Phone Number _______________________________ Technician Name ______...

Страница 2: ...AZARD Failure to follow this warning could result in personal injury death and or property damage Do not store or use combustible materials gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING FIRE EXPLOSION ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury death or property damage Do not use this unit if any par...

Страница 3: ... 5 second ignition period If the burners do not light within 15 minutes of the initial call for heat there is a lockout 11 Set the temperature selector on room thermostat to desired setting FIRE AND EXPLOSION HAZARD Failure to follow this warning could result in personal injury death and or property damage 1 If the main burners fail to light or the blower fails to start shut down gas heating secti...

Страница 4: ...de With the SYSTEM control set to COOL your unit will run in cooling mode until the indoor temperature is lowered to the level you have selected On extremely hot days your unit will run for longer periods at a time and have shorter off periods than on moderate days Gas Heat Mode With the SYSTEM or MODE control of your indoor thermostat set to HEAT your unit will run in heating mode until room temp...

Страница 5: ...05 5 Specifications are subject to change without notice 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 7 OFF ON MAIN STEP 8 STEP 5 72 STEP 10 STEP 6 STEP 9 O P E N A07662 Fig 4 To Start Unit Gas Heat ...

Страница 6: ...bject to change without notice 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 6 STEP 5 A07663 Fig 5 To Shut off Unit Gas Heat 90 STEP 1 STEP 2 CL O S E 72 STEP 4 5 OFF ON MAIN STEP 3 A09194 Fig 6 To Start Unit Electric Cooling ...

Страница 7: ...the accessory economizers and factory installed economizers Table 1 Replacement Filter Sizes Unit Size Filter Size 24 040 060 2 each 20 x 12 x 1 508 x 305 x 25 mm 30 040 060 2 each 20 x 12 x 1 508 x 305 x 25 mm 36 060 090 2 each 20 x 12 x 1 508 x 305 x 25 mm 42 060 090 1 each 24 x 14 x 1 610 x 356 x 25 mm 24 x 16 x 1 610 x 406 x 25 mm 48 090 115 130 1 each 24 x 14 x 1 610 x 356 x 25 mm 24 x 16 x 1...

Страница 8: ...ervice personnel Contact your dealer for the required annual maintenance Condensate Drain The drain pan and condensate drain line should be checked and cleaned at the same time the cooling coils are checked by your dealer Compressor All compressors are factory shipped with a normal charge of the correct type of refrigeration grade oil A compressor should rarely require additional oil Condenser Out...

Страница 9: ...el housing and motor 7 Inspection of all supply air and return air ducts for leaks obstructions and insulation integrity Any problems found should be resolved at this time 8 Inspection of the unit base to ensure that no cracks gaps etc exist which may cause a hazardous condition 9 Inspection of the unit casing for signs of deterioration 10 Inspection of all electrical wiring and components to assu...

Страница 10: ...10 46202200205 Specifications are subject to change without notice Copyright 2019 International Comfort Products Lewisburg TN 37091 USA Replaces 462022002204 ...

Отзывы: