HP103 Plasma Torch Height Controller
- - 20 - -
On opposite, the parameter is smaller, sensitive will be lower and the running
stability will be higher. So a appropriate coefficient selected can get a good
balance between the sensitive and stability.
•
RP102: Control voltage zero adjustment
•
RP31: Arc voltage display value adjustment
•
RP225: Arc voltage delay input time setup.
The arc voltage will be affected seriously during the leading arc. So the arc
voltage will be delay to put in the circuit.
•
RP403: Torch cutting end, torch rise time.
•
JP1: Set down input the external arc voltage.
Set up input the internal imitation arc voltage.
•
JP2: Select the type of Up limited switch.
Set down use the Normally open spot.
Set up use the Normally closed spot.
•
JP3: Select the type of Down limited switch.
Set down use the Normally open spot.
Set up use the Normally closed spot.
•
JP5: Select the type of proximity switch.
Set up use NPN normally closed.
Set down use PNP normally open.
•
JP6: Set isolation shield delay.
•
JP7: AUTO/MANUAL signal (EXAUTO)
Set up AUTO with low electricity level.
Set down AUTO with high electricity level.
C