Safety 

In operation, this heater is VERY HOT— do not touch any part of the heater while it is turned on. Do 
not touch any part until 30 minutes after it is turned off. 
 
This appliance is not intended for use by persons (including children) with reduced physical, sensory 
or intellectual capabilities, or lack of experience and knowledge, unless they have been given super-
vision or instruction concerning use of the appliance by a person responsible for their safety. Children 
should be supervised to ensure they do not play with the appliance. 
 
Do not allow any cables, furnishings, flammable materials or other items come in contact with any 
surface of the Flush Mount Enclosure. 
 
If installed in wet areas, the heater switches or controls must be located so that they cannot be 
touched by persons in the bath or shower. 
 
The Flush Mount Enclosure needs to be installed as per the installation instructions paying special 
attention to the minimum clearances. The heater needs to be mounted on a rigid bracket or fixing.  
 
See the heater Operations, Installation and Maintenance Manual for the heater specific guidelines. 
 
  

Maintenance

 

The Flush Mount Enclosure is made from durable materials, however regular care and maintenance 
of your product will help prolong its life. 
 
It is recommended that you wipe down your Flush Mount Enclosure.  With a soft cloth and mild deter-
gent gently wipe the surfaces of the FME to remove the built up contaminants from the environment. 
Then with a clean cloth ensure all detergent is removed. 
  
All chemicals in the atmosphere including cigarette smoke, pollution etc. will tarnish the surface of 
the Flush Mount Enclosure. In this case, additional cleaning and maintenance may be required. The 
cleaning process at least every three months will reduce the amount of build up and keep it looking 
as best it can. If the Flush Mount Enclosure is in a corrosive environment eg. salt spray, we recom-
mend that you clean the FME every week.  
 
Before cleaning or inspection activity, the heater must be switched off and cooled down completely. 
Do not use any abrasive materials or products to clean the Flush Mount Enclosure, this includes sol-
vents, citrus based cleaners or other harsh cleaning products. 
 
When handling the Flush Mount Enclosure, ensure that your hands are clean or that you use clean 
gloves as grease or dirt can mark the surface of the heater. 
 
Do not use high pressure water to clean Flush Mount Enclosure. It is not recommended to hose 
down the FME and heater as water may penetrate the roof cavity. 

Содержание THE 1800

Страница 1: ...OPERATION INSTALLATION AND MAINTENANCE MANUAL Flush Mount Enclosure for Heatstrip Elegance THE Range ...

Страница 2: ...eatly install the HEATSTRIP into a ceiling They are available for all HEATSTRIP Elegance models and are supplied as a one piece unit suitable for mounting individual heaters Flush mounting can be used with any building grade ceiling materials An ideal mounting height is 2 3m 2 5m with a maximum ceiling height of 2 7m in a fully enclosed outdoor environ ment Maximum mounting heights should be stric...

Страница 3: ...3 Flush Mount Enclosure Dimensions PART No MODEL A mm B mm C mm THEAC 040 THE1800 1080 1024 1020 THEAC 041 THE2400 1310 1254 1250 THEAC 042 THE3600 1910 1854 1850 VIEW FROM UNDERNEATH VIEW FROM TOP ...

Страница 4: ...Enclosure The enclosure has a number of openings for ventilation and air movement into the ceiling space these openings must not be covered The enclosure shall under no circum stances be covered with insulating material or similar material It is recommended to use only the provided holes in the ends of the enclosure for mounting Ensure all clearances detailed in the HEATSTRIP ELEGANCE PRODUCT MANU...

Страница 5: ... only the provided holes in the ends of the enclosure for mounting The minimum distance between the back of the enclosure and any building material is 150mm The minimum distance between the sides of the enclosure and any support structure is 50mm The minimum distance between adjacent enclosures is 200mm VIEW FROM BELOW Ceiling removed VIEW FROM SIDE ...

Страница 6: ...he spacing of the brackets are listed in the table STEP 2 Screw the FME into the battens NOTE screws are not included STEP 3 If there is no roof ac cess connect the heater to the power source ensure the power is OFF STEP 4 Lift the heater into the FME ensuring the brackets are to the side of the mounting cut outs STEP 5 Push the heater to the left ensuring the brackets engage in the mounting hole ...

Страница 7: ...m durable materials however regular care and maintenance of your product will help prolong its life It is recommended that you wipe down your Flush Mount Enclosure With a soft cloth and mild deter gent gently wipe the surfaces of the FME to remove the built up contaminants from the environment Then with a clean cloth ensure all detergent is removed All chemicals in the atmosphere including cigaret...

Страница 8: ...ty product or components by Thermofilm or an authorized representative of Thermofilm Thermofilm does not participate in any site related costs or labour expenses incidental to replacement of parts repairing removing installing servicing transportation or handling of parts to complete products and assumes no liability on parts repaired or replaced without written authorisation Thermofilm shall not ...

Отзывы: