HEATSTRIP TGH34WL-2 Скачать руководство пользователя страница 3

1. This appliance must be used only for outdoor and
non-residential indoor use. This appliance must not be
installed or used in residential indoor areas.This appliance
shall only be used in an above ground open-air situation
with natural ventilation, without stagnant areas, where gas
leakage and products of combustion are rapidly dispersed
by wind and natural convection.

2. Any guard or other protective device removed for
servicing (conducted by an authorized person) must
be replaced before operating the heater.

3.  Children and adults should be alerted to  the
hazards of high surface temperatures and should
stay away to avoid burns or clothing ignition.

4. Children should be carefully supervised when they
are in the area of the heater.

5. Clothing or other flammable materials should not
be hung from the heater or placed on or near the
heater.

6. Do not perform maintenance until heater has been
turned off, and heater has cooled to room temperature.

7. Do not expose the burner to water or moisture. The
appliance must be protected from rain.

8. Do not use the heater if any of these parts are
exposed to water until the appliance is inspected or
repaired by an authorized service person.

9. The installer is to ensure that the requirements of
the local authority, local  gas  fitting regulations,
municipal building codes, and any other relevant
statutory regulations are carried out.

10. Certain materials or items, when stored under or
near the appliance, will be subjected to radiant heat
and could be seriously damaged.

11.  All  leak  tests  should  be  done  with  a  soap
solution. Never use an open flame to check for leaks.

12. Do not use the heater until all visible gas
connections have been leak tested.Never test for
leaks with an open flame. Prior to first use, at the
beginning of each season.

13. The radiant heater is NOT intended to be
installed on recreational vehicles or boats.

14. Do not attempt to alter the unit in any manner.

15. Do not paint any surface of the heater or reflector.

  WARNING

!

!

16. Burner and circulation air passageways of the
heater must be kept clean. Frequent cleaning may be
required as necessary.

17.  Check  the  heater immediately  if  any  of  the
following occurs:
- The heater does not reach temperature.
- The burner makes popping noise during use (a slight
noise  is  normal  when  the  burner  is  ignited  or
extinguished).

18. This appliance is not intended for use by young
or infirm person unless they have been adequately
supervised by a responsible person to ensure that
they can use the appliance safely.

19. Check for damage to the appliance regularly. If
damage to the appliance is suspected, discontinue
use immediately and contact the supplier or qualified
person  for repair.

20. Avoid inhaling fumes emitted from the heater's
first use. Smoke and odour from the burning of oils
used in manufacturing will appear. Both the smoke
and  odour  will  dissipate  after  approximately  30
minutes.

21. Storage of an appliance indoors is permissible
only if the cylinder is disconnected and removed from
the appliance.

22. Do not store a spare LP gas cylinder under or near
this appliance.

23. The heater head angle retaining pin must be
inserted  if transporting  the heater  to  ensure  no
damage occurs during transit.

24. Do not install in very windy locations. Do not
transport or move the heater while it is operating.

  WARNING

!

!

3

Содержание TGH34WL-2

Страница 1: ...jury or death Read this operating and assembly instruction thoroughly before installing or serving this heater WARNING FOR OUTDOOR AND NON RESIDENTIAL INDOOR USE ONLY THIS APPLIANCE MUST NOT BE INSTALLED OR USED IN RESIDENTIAL DOMESTIC INDOORS Appliance is to be protected from rain TO BE INSTALLED ONLY BY AN AUTHORIZED PERSON OPERATION INSTALLATION AND MAINTENANCE MANUAL Wall Mounted Radiant Gas H...

Страница 2: ...eep this Instruction Manual for convenient referral and for part replacement You need to contact Thermofilm Australia Pty Ltd 17 Johnston Court Dandenong South Victoria 3175 Australia Telephone 03 9562 3455 8 30am 5 00pm Mon Fri EST Email info thermofilm com au To obtain the correct replacement parts for your gas radiant heater please refer to the part numbers in this parts list The following info...

Страница 3: ...Never use an open flame to check for leaks 12 Do not use the heater until all visible gas connections have been leak tested Never test for leaks with an open flame Prior to first use at the beginning of each season 13 The radiant heater is NOT intended to be installed on recreational vehicles or boats 14 Do not attempt to alter the unit in any manner 15 Do not paint anysurface of the heater or ref...

Страница 4: ...shall comply with one of the following 1 An enclosure with walls on all sides but at least one permanent opening at ground level 2 Within a partial enclosure that includes an overhead cover and no more than two walls 3 Within a partial enclosure that includes an overhead cover and more that two walls the following shall apply At least 25 of the total wall area is completely open At least 30 of the...

Страница 5: ...FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN A FIRE OR EXPLOSION WHICH COULD CAUSE SERIOUS BODILY INJURY DEATH OR PERPERTY DAMAGE DANGER Ÿ Ÿ Ÿ Ÿ Grill Information Center FREE HELP Thermofilm Australia Pty Ltd is the expert on this product and trained to help you with 17 Johnston Court Dandenong South Victoria 3175 Australia Telephone 03 9562 3455 8 30am 5 00pm Mon Fri EST Email info t...

Страница 6: ... unnecessary twisting of the flexible hose After the assembly has been secured turn on the gas and check for leaks by brushing a soap and water solution over all connections The presence of bubbles will indicate a gas escape DO NO TEST FOR GAS ESCAPES WITH AN OPEN FLAME If you are unable to correct the leak by tightening the connections turn off the gas and contact your place of purchase immediate...

Страница 7: ...ce around air openings to combustion chamber Clearance from combustible material Provisions for accessibility and clearance for combustion and ventilating air supply Intallation Clearances Dimension and Clearance Detail 7 WARNING MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL FROM TOP 500mm add TGHSHIELD not included for 300mm SIDE 1000mm MINIMUM MOUNTING HEIGHT 2000mm Note Additional heatshield TGHSH...

Страница 8: ...501166D Pin Φ6 x 150mm 1 P05501164B R Cotter Pin 1 S020100223 Bolt M6 x150mm 1 S411M0606A Wing Nut M6 1 Screwdriver 1 Install heater to Wall Mounting Bracket Pan Head Screw M5x10mm Qty 3 Part S112M05102 Screwdriver Qty 1 Pin Φ6 x 150mm Qty 1 Part P05501166D Bolt M6 x 150mm Qty 1 Part S020100223 R Cotter Pin Qty 1 Part P05501164B Wing Nut M6 Qty 1 Part S411M0606A AA Battery Pan Head Screw M6x10mm P...

Страница 9: ...Parts Diagram 9 ...

Страница 10: ...acket Upper P033510484 1 13 Burner Bracket Lower P033510494 1 14 Head Bowl P03351050D 1 15 Heat Deflector P03351034D 1 16 Head AssemblyBracket P03351051D 1 17A Wall Mounting Bracket P03351040D 1 17B Protective Ring P05556002I 1 18 Tilt switch P05380005A 1 19 Electric Ignitor P02505032F 1 Gas valve Assembly Y0060887 1 Gas valve P03253002F 1 21 Micro Switch ON P05382007D 1 22 Micro Switch OFF P05382...

Страница 11: ...er 11 Install Heat Deflector Removeall the packing materials Install the Heat Deflector to the Head using 3 Pan Head Screws M5x10mm then tighten all the screws securely 1 Pan Head Screw M5x10mm Qty 3 Part S112M05102 2 Install Battery 3 Install Regulator with hose bracket For NG Model Only Pan Head Screw M6x10mm Pre assembly Qty 2 Part S112M06102 AA Battery Note Reglator with hose can be assembly a...

Страница 12: ...164B Wing Nut M6 Qty 1 Part S411M0606A Bolt M6 x 150mm Qty 1 Part S020100223 Install Heater 12 6 Remove the Finger Protective Rings from Trigger Install Red Cord for Trigger ON Black Cord For Trigger OFF Install Cords 4 Install Wall Mounting Bracket Install the wall mounting bracket to the wall with appropriate fixings for the material to be attached Masonry wood metal etc using 6 appropriate fast...

Страница 13: ... release then turn on gas at source 1 part liquid detergent 4 parts water GAS REQUIREMENTS TGH34WN NG Model This appliance is for use with Natural Gas only Ensure that inlet pressure to the regulator does not exceed 5 0 Kpa The approved inlet pressure to be 1 0 Kpa Apply the soap solution to all visible gas connections If bubbles appear in the soap solution the connections are not properly sealed ...

Страница 14: ...connections Always light the heater standing to the side of the heater never light the heater standing in front 1 Turn on the gas source 2 Pull the red Cord down and click will be heard and continue to hold for 10 seconds The tiles should turn to red color Release the string 3 If the burner does not ignite turn off the gas source Wait at least 5 minutes for gas to clear then retry If your heater s...

Страница 15: ...ded the heater be operated on high heat after cleaning to ensure the appliance is dry Try this procedure Proper care and maintenance will keep your heater in top operating condition and prolong its life Follow these cleaning procedures on a timely basis and your heater will stay clean and operate with minimum effort CAUTION Besureyour heaterisOFFand coolbeforecleaning CLEANING EXTERIOR PAINTED SUR...

Страница 16: ...facturer Thermofilm does not participate in any site related costs or labor expenses incidental to replacement of parts repairing removing installing servicing transportation or handling of parts to complete products and assumes no liability on parts repaired or replaced without written authorization Thermofilm shall not be liable for any default or delay in perfor mance of its warranty obligation...