1.1 Introduction 

This instruction manual describes the

 Heatstore

 

Recessed Warm Air Ceiling Heaters.  

The heater is designed for discreet positioning in a 
suspended 600mm ceiling within retail or    
commercial premises.  It can fit a recess as shallow 
as 210mm. 

1.2 General

 

All installations must be in accordance with the 
regulations in force in the country of use. 

These instructions must be handed to the user on 
completion of the installation. 

Installers and service engineers must be able to 
demonstrate competence and be suitably    
qualified in accordance with the regulations in 
force in the country of use. 

To ensure continued and safe operation it is     
recommended that the appliance is serviced 
annually. 
The heater outlet / inlet must not be obstructed 
during use. 

1.3

 

Electrical Supply

Electrical supply is 230/240V single phase,     
Neutral and Earth. The maximum cable inlet size is 
4mm².  
It is recommended that the electrical supply to the 
base unit in the heater is via an appropriate 
switched isolator in accordance with the    
regulations in force in the country of use and must 
be via a fused isolator having a contact separation 
of greater than 3mm on all poles. 
BMS control, time switches, room thermostats and 
door interlocks can be installed at the discretion 
and responsibility of the installer. 

All units must be wired in accordance with I.E.E 
regulations for the Electrical Equipment of    
Buildings and the installer should ensure that a   
suitable isolating switch is connected in the mains 
supply. 

1.4

 

Controller 

RF

The 

HSRCH3000RF

 and HSRCH4500RF

 heaters are

 

supplied without a controller. The

 RF

 

models will not

 

work without

 a RF 

controller. See section 5.1 for

 

more details. 

1.6 Location 

All units should be installed horizontally. It is     
recommended that the ceiling  heater is installed 
within the ceiling void or roof space. 

Care must be taken to allow complete free air 
movement into the inlet grilles of the unit to     
ensure the correct working operation of the   
heater. If the HSRCH3000RF or HSRCH4500 heaters
are mounted close to the wall or corner the     
discharge opening should be facing the wall. The 
minimum distance from the wall or corner is 0.8m

.

1.7 Clearance distances 

It is recommended that a minimum clearance of 
50mm is allowed around the case and 30mm 
above the heater. The clearance allows for cable 
entry and prevents combustible surfaces    
overheating.  

The minimum mounting height (floor to grille) is 
2.2m for the HSRCH3000RF and the HSRCH4500RF. 
The recommended mounting height is 2.5m for 
the HSRCH3000RF and HSRCH4500RF.

Heatstore RF Controllers

HSPBRF

HSTIRF

HSVTRF

1

 

.

 

General Information

Содержание HSRCH3000RF

Страница 1: ...information 1 Dimensions 2 Installation Details 3 Electrical Connections 4 Operation 5 Servicing Maintenance 6 RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF HSRCH4500RF INSTALLATION AND OPERATING MANUAL HSPBRF HSTIRF HSVTRF ...

Страница 2: ......

Страница 3: ...ats and door interlocks can be installed at the discretion and responsibility of the installer All units must be wired in accordance with I E E regulations for the Electrical Equipment of Buildings and the installer should ensure that a suitable isolating switch is connected in the mains supply 1 4 Controller RF The HSRCH3000RF and HSRCH4500RF heaters are supplied without a controller The RF model...

Страница 4: ... rests with the installer to ensure that protective safety wear such as hand eye ear and head protection is used during installation of the product Do not rest anything especially ladders against the product 1 10 Standards Units conform to the European electrical standard BS EN 60335 2 30 HSRCH3000RF and HSRCH4500RF HSRCH3000RF and HSRCH4500RF 1 General Information 2 Dimensions ...

Страница 5: ...recessed ceiling heaters are de signed to fit in place of a standard 600mm ceiling panel IT IS ESSENTIAL THAT THE CEILING FRAME IS ADE QUATELY SUPPORTED TO SUPPORT THE WEIGHT OF THE HEATER OR THAT THE HEATER IS INDIVIDUALLY SUP PORTED THERE IS PROVISION ON THE HEATER FOR CHAIN OR WIRE SUPPORT OR MOUNTING The weight of the HSRCH3000RF and HSRCH4500RF is 7kg It is the sole responsibility of the inst...

Страница 6: ...oller can control any number of heaters providing they are in he RF range For more details please follow the instructions supplied with the controller 4 2 Electrical connections Fig 8 Heater with terminal cover open Fig 9 Terminal cover detail HSPBRF HSTIRF Heatstore RF Controllers HSVTRF 4 2 Electrical Connections 4 Operation ...

Страница 7: ...obstruction of the free airflow by thermal cut outs If this happens the thermal cut outs switch off the appliance The ap pliance will not operate until the heater is discon nected from the mains supply and it has cooled down If this fault re occurs again refer to the section 6 4 fault finding 6 1 Maintanence 6 4 Fault Finding If the heater will not operate disconnect it from the mains and arrange ...

Страница 8: ...7 RF RF ...

Страница 9: ...8 Heatstore Unit 12 Access 18 Bristol BS11 8HT Tel 0117 9235 375 Fax 0117 9235 374 ...

Отзывы: