SUSPENSION POINTS 

1.8  Clearance distances 

1.9  Health and Safety 

Sole liability rests with the installer to ensure that all 
site safety procedures are adhered to during installa-
tion. 
Sole  liability  rests  with  the  installer  to  ensure  that 
protective  safety  wear  such  as  hand,  eye,  ear  and 
head  protection  is  used  during  installation  of  the 
product.  

Do not rest anything especially ladders against the 
product. 

1.10  Standards 

Units conform to the European electrical standard 
BS EN 60335-2-30  

HSSCH3000RF, HSSCH4500RF

HSSCH3000RF, HSSCH4500RF

1

 

.

 

General Information

2. Dimensions

Содержание HSPBRF

Страница 1: ...information 1 Dimensions 2 Installation Details 3 Electrical Connections 4 Operation 5 Servicing Maintenance 6 SURFACE WARM CEILING HEATERS MODELS HSSCH3000RF HSSCH4500RF INSTALLATION AND OPERATING MANUAL HSPBRF HSTIRF HSVTRF ...

Страница 2: ...ntrol time switches room thermostats and door interlocks can be installed at the discretion and responsibility of the installer All units must be wired in accordance with I E E regulations for the Electrical Equipment of Buildings and the installer should ensure that a suitable isolating switch is connected in the mains supply 1 4 Controller RF models The HSSCH3000RF and HSSCH4500RF will only oper...

Страница 3: ...Sole liability rests with the installer to ensure that protective safety wear such as hand eye ear and head protection is used during installation of the product Do not rest anything especially ladders against the product 1 10 Standards Units conform to the European electrical standard BS EN 60335 2 30 HSSCH3000RF HSSCH4500RF HSSCH3000RF HSSCH4500RF 1 General Information 2 Dimensions ...

Страница 4: ...low It is required that two 10 mm hanging rods stud bars support each appliance beam The rods pass through and into each appliance beam Support washers together with nuts locate and lock the appliance beams after adjustment to level the appliance Replace Shroud Halves The reverse of above Slide shrouds beneath and around base panel Se cure each shroud half to each appliance beam with machine screw...

Страница 5: ...ller can control any number of heaters providing they are in he RF range For more details please follow the instructions supplied with the controller 4 2 Electrical connections Fig 8 Heater with terminal cover open Fig 9 Terminal cover detail Heatstore RF Wireless Controllers HSPBRF HSTIRF HSVTRF 4 Electrical Connections 5 Operation ...

Страница 6: ...n of the free airflow by thermal cut outs If this happens the thermal cut outs switch off the appliance The ap pliance will not operate until the heater is discon nected from the mains supply and it has cooled down If this fault re occurs again refer to the section 6 4 fault finding 6 1 Maintenance 6 4 Fault Finding If the heater will not operate disconnect it from the mains and arrange for a cert...

Страница 7: ...7 RF RF ...

Страница 8: ...8 Heatstore Unit 12 Access 18 Bristol BS11 8HT Tel 0117 9235 375 Fax 0117 9235 374 ...

Отзывы: