background image

4

OPEN  OUTLET  TAP  FITTING

1.  Ensure electricity supply is switched off.

2.  Remove terminal cover (using a flat bladed screwdriver to relieve snaps located 

  towards the front of the terminal cover either side).

3.Plumb from the open outlet tap fitting using 15mm outside diameter copper pipe to  

the 15x15mm john guest fitting in the water heater. The tap set will have its own instal

-

lation instructions.

ELECTRICAL REQUIREMENTS

  (REFER TO FIGURE 2  - WIRING 

DIAGRAM).

  WARNING: THIS APPLIANCE MUST BE  EARTHED.

  CONNECT ONLY TO 230 / 240V AC SUPPLY.

  NOMINAL CROSS SECTION OF SUPPLY CABLE MUST BE AT LEAST  

 15mm

2

.

  A DOUBLE POLE ISOLATING SWITCH WITH A CONTACT SEPARATION OF

  AT LEAST 3mm  IN EACH POLE MUST BE INCORPORATED IN THE 

 SUPPLY.

  ELECTRICAL INSTALLATION MUST CONFORM TO THE CURRENT I.E.E. 

  WIRING REGULATIONS.

1.   Remove terminal cover (as described above).

2.   Strip the outer sheath and insulation on the cable to the required lengths, making 

  sure the outer sheath of the cable will be held in the cable grip when the connections 

  are made.

3.   Loosen the top screws securing the bar at the cable grip.

4.   Pass the cable through the cable grip.

5.   Make the connections to the terminal block as follows:

    -Live (brown or red wire) to terminal marked “L”

    -Neutral (blue or black wire) to terminal marked “N”

  -Earth (green or green/yellow wire) to terminal marked   

6.   Secure the cable in the cable grip by tightening the two screws.

7.   Set the adjustable thermostat by rotating the control to the required temperature, the 

  reading being taken from the top of the dial. It is recommended that it is set to 

  lowest acceptable temperature to meet user requirements. This will minimise the 

  risk of scalding and reduce the level of scaling in hard water areas.

8.   Replace terminal cover.

OPERATION

DO NOT SWITCH ON HEATER UNTIL IT IS FILLED WITH WATER

1.   Fill with water by opening valve/tap and leaving open until a full bore of water  

  flows from the outlet.

2.   Close valve and switch on water heater at double pole isolating switch. The heater 

  will heat water to the temperature set on the thermostat.

3.  Check water is heating correctly.

      7 litre 1.2kW  - after 10 mins water temperature will increase by 20°C

Содержание HS55/3/10N

Страница 1: ...ructions before starting work Please leave this leaflet with the user following installation PACK CONTENTS Heater Spout Valve Fixing screws and plugs Installation and User Instructions WARNING This water heater must only be installed by qualified persons 36005793_issue_07 HEATSTORE OPEN OUTLET WATER HEATERS ...

Страница 2: ...uced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Children must be supervised to ensure they do not play with the...

Страница 3: ... removal of the element plate 210mm b When using the outlet spout it will swing over the sink or sinks to be supplied c There are no hidden services where the wall is to be drilled 2 Mark the position of the fixing holes as shown in Figure 4 3 Drill and plug the hole positions 4 Screw in the top two screws leaving head 3mm from the wall 5 Hang the heater on the two top screws 6 Screw in bottom scr...

Страница 4: ...the cable grip when the connections are made 3 Loosen the top screws securing the bar at the cable grip 4 Pass the cable through the cable grip 5 Make the connections to the terminal block as follows Live brown or red wire to terminal marked L Neutral blue or black wire to terminal marked N Earth green or green yellow wire to terminal marked 6 Secure the cable in the cable grip by tightening the t...

Страница 5: ...of water inside the heater and is normal for heaters of this type It does not indicate that the valve tap is faulty and overtightening of the valve tap can result in damage Name Heatstore Model HS55 3 7N HS55 1 7N HS55 3 10N Volume Litres 7 7 10 V40 9 9 11 Load Profile XXS XXS XXS Energy Efficiency Class C C C Energy Efficiency 31 4 31 4 31 9 Annual electricity consumption kWh 587 587 578 Daily fu...

Страница 6: ...ELLOW WIRE ELEMENT THERMAL FUSE THERMOSTAT TERMINAL BLOCK DOUBLE POLE ISOLATING SWITCH BROWN BLUE GREEN YELLOW MAINS SUPPLY L N FIG TWO WIRING DIAGRAM AC ONLY OUTLET INLET CABLE CLAMP TERMINAL BLOCK EARTH POST ELEMENT THERMOSTAT CONTROL FIGURE 1 INTERNAL LAYOUT DRAIN PLUG THERMAL CUT OUT CAPILLARY STAT ...

Страница 7: ...e No water flow 1 Frozen Switch off electrical power and allow to thaw at room tem perature Do not switch on again until full water flow restored and full checks made for leaks and electrical safety 2 No mains supply Check mains Continuous water flow Faulty valve tap Check and replace 240 FIXING HOLE 240 57 105 120 X Y 140 2 KEYHOLE FIXING SLOTS 6mm WIDE 300 COLD WATER INLET VALVE FIGURE 4 DIMENSI...

Страница 8: ...ged the repaired or new parts will be delivered by the Manufacturer free of charge Provided further that in respect of parts or components not of the Manufacturer s manufacture he will give the user a guarantee if any which the Manufacturer may have received from the supplier of such parts or components in respect thereof but not so as to impose on the Manufacturer of such parts or components a li...

Отзывы: