Installation Instructions 

 

ALL WIRING AND INSTALLATION MUST BE SUPERVISED BY A QUALIFIED ELECTRICIAN 

 

WARNING: DO NOT INSTALL THIS SHOWER IN A ROOM WHERE IT MAY BE SUBJECT TO FREEZING. 

 

We recommend that the installation is done in the following sequence. 

 

a.  Fixing the shower to the wall 
b.  Plumbing 
c.  Electrical connections 

 

a. 

Fixing the shower to the wall 

 

1. 

Position the riser rail at the height recommended in diagram  5 and mark its position (also see separate accessories 
fitting instructions sheet). 

2. 

Position the heater so that the top of the unit is horizontal and level with,  

or up to

 

0.6 metres (2ft) maximum below the top of the riser rail.

 

Choose a flat piece of wall to avoid the possibility of distorting the 
backplate thus making the front cover a poor fit. 

 

3. 

Adjust the position to get the most convenient arrangement taking the 
following into account. 

  The possible need to use the handset over the sink for hair washing etc. 

 

 

The heater must not be mounted in direct spray from the handset. 

 

  The handset must not be able to come into contact with used water in the 

cubicle, bath or basin.                                                                                                  
If it can, even after the hose has been retained by the soap dish (see 
separate accessories fitting instructions sheet), then a vacuum breaker 
must be fitted.                                                                                                            
It should be noted that these devices are liable to minor leakage so they 
must be positioned so that any drips are not detrimental. 

 

4. 

Fix the riser rail with screws provided (see separate accessories fitting 
instructions sheet).  

 

 

5. 

Decide the position of the electrical cable to the unit.                           
If top or bottom entry is chosen (according to diagram 4), cut 
away the walls in the backplate as shown in diagram 6. 

 

6. 

Decide the position of entry of the cold water pipe into the unit.  
If top, cut away the backplate.                                                                
If rear, please read the section on plumbing.                                          
If bottom, remove the front cover and cut away the detachable 
corner section as shown, 

 

7. 

If you have not yet done so, remove the front cover of the unit by 
undoing the retaining screws at the top and bottom of the unit 
and lifting the cover off.                                                                      
Your shower is provided with 2 fixing positions in the backplate 
(see diagram 4).                                                                                
The top-fixing hole is a “key-hole” slot (another key-hole is 
provided for alternate fixing), and should be marked and drilled 
first.                                                                                    
Tighten top screw with head protruding about 10mm from the 
wall and hook the backplate over the screw head.                              
This allows for correct and accurate alignment of your shower 
before marking and fixing the bottom position.                                        
You may not wish to tighten up both screws at this stage as 
the holes are elongated to allow for adjustment after other 
connections have taken place.  

 
 

Diagram 6 

Содержание AQUA PROFILE

Страница 1: ...Including both White and Chrome Variants SHOWER HANDBOOK IMPORTANT This booklet should be left with the user after installation and demonstration...

Страница 2: ...ow to temperature Once a temperature setting to your liking has been achieved knob E will rarely need adjusting eg adjust for variations of incoming mains water temperature between summer and winter 5...

Страница 3: ...ure light illuminating see How to use your shower note 7 7 As a further safeguard a thermal cut out switches the power off if the water temperature climbs above the set limit and the overheat light wi...

Страница 4: ...partment on 0117 923 5375 Fitting instructions are provided PROFESSIONAL SERVICE If the above checks fail to restore the performance you should seek professional help The person who installed the show...

Страница 5: ...then a vacuum breaker must be fitted It should be noted that these devices are liable to minor leakage so they must be positioned so that any drips are not detrimental 4 Fix the riser rail with screw...

Страница 6: ...ly whilst avoiding excess finding its way into the shower operating parts 5 With stop valve connected flush the pipe work through to remove any particles etc before making the final connection to the...

Страница 7: ...the lights and then replace drive in position shown in diagram 9 Check that when the flow valve is turned fully anti clockwise that all lights are visible Re fit the cover and secure with top and bott...

Страница 8: ...Full details of terms and conditions are available on request from MANUFACTURED FOR HEATSTORE ADDVENT VICTORIA ROAD AVONMOUTH BRISTOL BS11 9DB Website www heatstore co uk Leaflet No 555 2110 31A...