HeatStar THP750S Скачать руководство пользователя страница 3

 

 

 

 

 

                      

 

THERMOFILM AUSTRALIA   27 Rosalie Street, Springvale VIC 3171 

Ph: +61 (0) 3 9562 3455       Fx: +61 (0) 3 9548 3979      www.thermofilm.com.au 

 

 

 

H E A T S T A R  

R  A  D  I  A  N  T     P  A  N  E  L     H  E  A  T  E  R  S

 

2.   Specification Data 

Model 

Power (W)

 

Voltage (V) 

Dimension (mm) 

Rating 

THP750 

750W 

230-240V 

1190 x 590 x 30mm 

IP44 

THP450 

450W 

230-240V 

1080 x 380 x 25mm 

IP44 

 

3.   Selection Guidelines 

For comfort heating applications, a heat load calculation should be made and HEATSTAR units 

selected to meet the heating requirements. 

 

Model THP750S 

The THP 750S model is designed for ceiling mounting.  As a guideline for normally insulated areas with 

a ceiling height from 2.4 to 3.6m, allow 15 square meters of floor space per heater. 
 

For example, a room of 45 square meters would require 3 x THP 750S units  

(45 sq m ÷ 15 sq m = 3 units) 

 
Note: The THP 750S will heat larger rooms than 15 square meters but a longer warm up time is 

required. 

 
For zone heating applications, allow one (1) THP 750S unit per person, and mounting height should be 

2.4 meters. 

 

Model THP450 

The THP 450 model is suitable for ceiling or wall mounting.  As a guideline for normally insulated areas 

with ceiling height of 2.4 to 3.2m, allow 9 square meters of floor space per heater. 

 
For example, a room of 18 square meters would require 2 x THP 450 units  

(18 sq m ÷ 9 sq m = 2 units) 

 
Note: The THP 450 will heat larger rooms than 9 square meters but longer warm up time is required. 

 

4. Installation and Operating Instructions – THP 750S 
 
4.1  Model THP750S 

The THP 750S is designed to mount directly onto ceilings, suspend from high ceilings, fit into T-Bar 

ceilings, or flush mount in plastic ceilings. 

 
It is recommended that an appropriate thermostat control and or timer control is used in conjunction 

with the THP 750S. 

 

4.2  Ceiling Mounting 

Fix mounting bracket in the desired location 
with suitable fixing devices more than capable 

of safely supporting the heater. 

 
The fixing devices should be suitable for the  

type of mounting surface; plaster, timber,  

concrete etc 

 
 

 

Position the heater onto the bracket 
 

Отзывы: