K. Troubleshooting Your Swimming Pool Heat Pump: Parameter Settings 

 
1.  The heat pump has 11 control parameters from 00 to 10. 
2.  The parameters can be viewed but not changed while in operation mode. They can 

only be changed in stand-by mode. 

3.  Use the SET button to scroll through the parameters. 
4.  If you need to change a parameter make sure the heat pump is in standby mode. 

 

Parameter

 

Description

 

Range

 

Default Setting

 

Remarks

 

00 

Setting of cooling temp 

8 – 28°C 

12°C 

For technician only 

01 

Setting of heat temp 

15 – 40°C 

 

To be set by user 

02 

Defrosting period 

30 – 90 min. 

45 minutes 

For technician only 

03 

Coil temp. start 

defrosting 

0 ~ -30°C 

0°C 

For technician only 

04 

Coil temp. stop 

defrosting 

2 – 30°C 

13°C 

For technician only 

05 

Defrosting time 

1 – 12 min 

8 minutes 

For technician only 

06 

System number 

1 – 2 

May not be changed 

07 

Re-start after power 

failure 

0 / 1 

1 = ja. 

For technician only 

08 

Available Modes: 

Cooling only= 0 

H cooling = 1 

Heating only= 3 

 
 

0 – 3 

 
 

 
 
For technician only 

09 

Work method. 

May not be changed 

10 

Setting of water temp. 

(auto mode ) 

30°C 

30°C 

For technician only 

 
5.  With the exception of Parameter 01 (setting the pool temperature set point) these 

parameters are usually only changed by a service technician. 

6.  Most parameters can not immediately be changed, even in standby mode. If you are 

sure you want to change a parameter proceed as below. 

7.  Before you change a parameter write down what it was set on. 
8.  In standby mode use the SET button to chose the parameter that needs changing. 
9.  Press the up and down arrows at the same time for about 5 seconds until you hear a 

small bleep. This unlocks the parameter to enable setting. 

10. Use the up and down arrow to set the parameter to the new desired level. 
11. After a few seconds the panel will revert to the standby mode with the new setting 

stored. 

12. If you need to check the parameter setting use the SET button to display that 

parameter. 

 

L. Accessories 

The heat pump has a housing and cover plate to allow the digital control panel it to be 
mounted remotely if required. A 5m extension line with socket for this purpose is provided 
with the kit. 

 

 

 

Содержание WBR-17.0H-A

Страница 1: ...ompressor and a 5 year parts warranty on the titanium heat exchanger Please contact your supplying dealer in the event of a claim This heat pump is designed for domestic use between May and September...

Страница 2: ...Connecting Pipe Work C Sizes D Starting the Heat Pump E Setting the Temperature F Checking the Status G Changing the Mode H Auxiliary Mode I Winterising and Maintenance J Troubleshooting Error Codes K...

Страница 3: ...be able to tolerate this B Connecting Your Swimming Pool Pipe Work 1 The pool water is fed through the heat pump by a swimming pool pump 2 The heat pump must be installed after down stream the swimmin...

Страница 4: ...HeatSeeker Swimming Pool Heat Pump Page 4 of 10 C Sizes of Your Swimming Pool Heat Pump WBR 17 0H A WBR 21 0H A S A 855 955 B 660 660 C 660 660 F 370 370 G 110 110...

Страница 5: ...de Set Aux 3 After a few seconds the display shows ROOM and a temperature This is the temperature of the air surrounding the heat pump 4 Push the START STOP button and await the display to show the in...

Страница 6: ...to the standby mode after a few seconds 5 Restart the heat pump by pressing the START STOP button 6 After the 2 3 minute delay the heat pump will re start with the new set temperature F Checking the...

Страница 7: ...ection H Auxiliary Mode of Your Swimming Pool Heat Pump 1 The AUX button on the heat pump is not used 2 When pressed the AUX button may make a wavy line symbol appear and disappear on the display but...

Страница 8: ...sensor fault error PP 01 Sensor interrupted or short circuited Test line sensor and socket May have to be replaced Water temperature out sensor fault error PP 02 Sensor interrupted or short circuited...

Страница 9: ...1 Heating only 3 0 3 3 For technician only 09 Work method 0 0 May not be changed 10 Setting of water temp auto mode 30 C 30 C For technician only 5 With the exception of Parameter 01 setting the pool...

Страница 10: ...roll Number of Fans 1 Input Power of Fan W 200 200 Fan Rotation Speed rpm 830 830 Noise Level dB 60 60 Water Connection inches 1 1 Water Flow Rate m 3 h 5 8 6 10 Water Pressure Drop KPa 16 16 Unit Dim...

Отзывы: