4
Revised 2021
STAINLESS STEEL BRIDGE
The stainless steel bridge is not recommended as a cutting
surface and should not be used as one.
INDICATOR LIGHT
The LED light near the center of the unit (2) illuminates to indi-
cate that the heat cycle is in process. The light will turn yellow
while the plate is heating and then red when the plate reaches
sealing temperature.
GFCI
The GFCI (3) is located on the rear surface of the unit. The
GFCI may need to be reset if the wrapper gets wet or other
ground faults arise. Do not reset the GFCI, if visible seal
plate damage is present.
1
2
3
MACHINE TECHNOLOGY & COMPONENTS
THERMISTOR TEMPERATURE CONTROL
Due to the rapid response of the seal plate and residual heat that can remain from previous cycles, a thermistor is
incorporated as a temperature control device. The seal cycle can be shorter than 3 seconds when residual heat is present in
the seal plate. The thermistor, located within the seal plate, regulates the temperature of the seal plate to ensure that the
temperature peaks at 370˚F.