Heatrae Sadia UTC 99 Скачать руководство пользователя страница 2

2

CONTENTS

SECTION 

      PAGE

1.0 

INTRODUCTION 

     2

2.0 

TECHNICAL 

SPECIFICATION 

   3

3.0 

INSTALLATION 

     4

4.0 

COMMISSIONING 

     9 

5.0 

EXPLANATION 

TO 

USER 

    9

6.0 

MAINTENANCE 

     10

7.0 

FAULT 

FINDING 

     12

8.0 

SPARE 

PARTS 

     14

9.0 

GUARANTEE 

     15

10.0 

ENVIRONMENTAL 

INFORMATION 

   15

11.0 

SPARES 

STOCKISTS 

    16 

 

   

1.0 INTRODUCTION

Thank you for purchasing a Heatrae Sadia UTC 99 vented water heater. The 

UTC 99 water heater is manufactured in the UK to the highest standards and 

has been designed to meet all the latest relevant safety specifications.

This UTC99 water heater must be installed, commissioned and maintained 

by a competent person only. Please read and understand these instructions 

prior to installing your vented water heater. Particular attention should be paid 

to the section headed IMPORTANT INSTALLATION POINTS. 

Following installation and commissioning, the operation of the heater should 

be explained to the user and these instructions left with them for future 

reference.

This appliance can be used by children aged from 8 years 

and above and persons with reduced physical sensory or 

mental capabilities or lack of experience and knowledge if they 

have been given supervision or instruction concerning use 

of the appliance in a safe way and understand the hazards 

involved. Children shall not play with the appliance. Cleaning 

and user maintenance shall not be made by children without 

supervision.

Children must be supervised to ensure they do not play with 

the appliance.

Содержание UTC 99

Страница 1: ...1 Fitting Instructions and User Guide UTC 99...

Страница 2: ...understand these instructions prior to installing your vented water heater Particular attention should be paid to the section headed IMPORTANT INSTALLATION POINTS Following installation and commissio...

Страница 3: ...lared load profile XS XS The water heating energy efficiency class of the model C D The water heating energy efficiency in 32 3 29 2 The annual electricity consumption in kWh 570 631 Daily fuel consum...

Страница 4: ...or worktop 3 1 2 The UTC 99 can be installed either as an Open Outlet or Cistern Fed type unit when used with the appropriate fittings DO NOT connect directly to the mains water supply 3 1 3 OPEN OUT...

Страница 5: ...ways be to the top of the unit 3 1 8 Enough space should be left at the top above the unit to allow for pipe connections Refer to Fig 01 to determine a suitable position for the heater 3 1 9 Ensure th...

Страница 6: ...2 7 The cold water supply can either be taken from the cold water mains or from a cold water feed cistern complying with Water Byelaw 30 with a minimum recommended pressure of 0 04 MPa 0 4 bar 3 2 8 T...

Страница 7: ...and be arranged to discharge into the cold water feed cistern The vent pipe must have a minimum bore of 19mm DO NOT connect any pressure relief device to the vent pipe of this water heater 3 2 12 The...

Страница 8: ...ons Ensure the electrical supply is switched off before making any connections to the water heater 3 3 1 The unit is supplied fitted with a 0 75m 3 core 1 5mm2 flexible cable The electricity supply sh...

Страница 9: ...ures in the range of 10 to 70 C To avoid any risk of freezing when the heater is not in use for long periods during the winter months do not switch off the electrical supply and set the thermostat to...

Страница 10: ...nt operation 5 7 LITERATURE Hand over the Installation and user instructions 6 0 MAINTENANCE WARNING Disconnect from all electrical supplies before beginning any work on the water heater Water contain...

Страница 11: ...ting pad from the terminal housing 6 3 3 Disconnect the electrical terminations to the thermostat Disconnect earth links to the earthing stud 6 3 4 Remove the element plate assembly by unscrewing the...

Страница 12: ...uld a problem occur the table overleaf should enable most faults to be identified with ease Fault Finding should be carried out by a competent person and any replacement parts used should be authorise...

Страница 13: ...Checkmains water turned on 1 Cold watersupply not No water flow General 2 Checkforobstructions supply 2 Blockage in cold water connections to tapset 1 Checkwater correctly installed 1 Open Outlet taps...

Страница 14: ...regularly maintained Maintenance and servicing should be carried out by a competent person and any replacement parts used should be authorized Heatrae Sadia spare parts DESCRIPTION CODE No Element pl...

Страница 15: ...tions 4 The unit has been used only for heating potable water The unit is not guaranteed against damage by frost and the inner container with integral immersion heater is not guaranteed against excess...

Страница 16: ...67 Parts Centre Tel 0344 292 7057 www partscentre co uk Newey Eyre Unit 3 5 Wassage Way Hampton Lovett Ind Estate Droitwich Worcestershire WR9 0NX Tel 01905 791500 Fax 01905 791501 UK Spares Ltd Unit...

Отзывы: