10.0 FAULT FINDING

Disconnect the electrical supply before removing the terminal cover. It
is recommended that any service operations on the UTC 15 heater are
carried out by a competent person.

NOTE: 

Use only Heatrae Sadia approved spare parts. Replacement of

any parts with components not recommended by Heatrae Sadia will
invalidate the guarantee and may render the installation dangerous.

ACTION

POSSIBLE CAUSES

FAULT

1. Check electrical supply

1. Electrical supply fault

Water not heating

h

/ h

l

necessary replace

thermostat operation. If

operated reset and check

2. Check cut-out, if

2. Thermal cut-out tripped

necessary

operation, replace if

3. Check thermostat

3. Thermostat fault

replace.

resistance. If faulty

continuity and insulation

4. Check element for circuit

4. Element fault

supply is on.

1. Check mains water

turned on

1. Cold water supply not

No water flow - General

2. Check for obstructions.

supply

2. Blockage in cold water

connections to tapset

1. Check water

correctly installed

1. Open Outlet tapset not

Outlet installations

No water flow - Open

2. Check for obstructions. 

2. Blockage in tapset

1. Check for obstructions. 

1. Blockage in tapset

Fed installations

No water flow - Cistern

float valve.

Check operation of cistern

cistern tank is turned on.

2. Check water supply to

2. Cistern tank empty

float valve.

Check operation of cistern

equal to outlet flow rate.

and that inlet flow rate is

cistern tank is turned on

1. Check water supply to

as outlet flow rate

1. Cistern not filling as fast

installations

reduces - Cistern Fed

Water flow gradually

necessary.

obstructions, clear as

2. Check vent pipe for

2. Vent pipe blockage

Содержание UTC 15

Страница 1: ...d Water Heater HEA HEA HEA HEA HEATRAE SADIA TRAE SADIA TRAE SADIA TRAE SADIA TRAE SADIA The quality name in water heating Please read and understand these instructions before starting work Please lea...

Страница 2: ...he UTC 15 vented water heater is designed to be fitted under a sink or worktop 1 2 The UTC 15 can be installed either as an Open Outlet or Cistern Fed type unit when used with the appropriate fittings...

Страница 3: ...support the full weight of the unit see TECHNICAL SPECIFICATIONS and that there are no hidden services electricity gas or water below the surface of the wall 2 5 The unit should be fixed to the wall...

Страница 4: ...ir of pillar taps PACK S 95 970 312 Basin hot tap PACK T 95 970 313 Basin cold tap matches Pack S 3 3 The cold water supply may be taken from the cold water mains or from a cold water feed cistern com...

Страница 5: ...m internal diameter of 19mm The vent pipe must be unobstructed rise continuosly and be arranged to discharge into the cold water feed cistern DO NOT connect any pressure relief device to the vent pipe...

Страница 6: ...tch on the electrical supply until the unit has been filled with water and checked for leaks 5 2 Check that all installation and electrical requirements have been met 5 3 Check that all water and elec...

Страница 7: ...screws tapped jacking points are provided Remove any loose scale from the container Carefully clean off any scale from the element and thermostat pocket DO NOT clean scale from interior container wal...

Страница 8: ...is available for your UTC 15 water heater Please refer to the Rating Label on the side of your heater before ordering to ensure the correct spare part is obtained DO NOT REPLACE WITH PARTS NOT RECOMME...

Страница 9: ...ulty continuity and insulation 4 Check element for circuit 4 Element fault supply is on 1 Check mains water turned on 1 Cold water supply not No water flow General 2 Check for obstructions supply 2 Bl...

Страница 10: ...12 3 The indicator light will be illuminated when the unit is heating 12 4 To ensure the heater continues to operate at its optimum performance it should be periodically maintained in accordance with...

Страница 11: ...s not been tampered with and has been regularly main tained as detailed in these instructions 4 The unit has been used only for heating potable water The unit is not guaranteed against damage by frost...

Страница 12: ...HEATING LIMITED Hurricane Way Norwich NR6 6EA Tel 01603 420100 General 01603 420330 Service Fax 01603 420149 HEA HEA HEA HEA HEATRAE SADIA TRAE SADIA TRAE SADIA TRAE SADIA TRAE SADIA The quality name...

Отзывы: