Heatrae Sadia Multipoint ECO Скачать руководство пользователя страница 3

3

 

`

All appliance pipe fittings are made via 22mm compression fittings, threaded 3/4”BSP male parallel.

 

`

A servicing valve must be incorporated into the cold water supply

 

`

The expansion vessel must be connected between the check valve and the appliance.

 

`

It is recommended that the outlet point of the drain pipework be at least 1 metre below the level of the base of the 

appliance (this can be achieved by attaching a hose to the drain tap outlet spigot).

 

`

Safety discharge connections (including the tundish) must to conform to G3 building regulations.

3. Installation - Water

12

4

6

7

5

8

9

10

3

2

1

11

8

2

9

9

2

Figure 4: Typical installation - schematic (not to scale)

Item

Description

1

Cold Water Mains in

2

Service Valve (not supplied)

3

Pressure Reducing Valve (PRV)

4

Balanced Cold Water Draw Off

5

Check Valve

6

Expansion Vessel

7

Expansion (Pressure) Relief Valve

8

Tundish

9

To Drain (Waste)

10

Hot out

11

Water heater

12

Temperature and Pressure Relief Valve

Table 2: Typical installation table

WARNING

 

`

Under  no  circumstances  should  the 

factory  fitted  Temperature/Pressure 

Relief Valve be removed.

 

`

The cold water controls supplied MUST 

be  fitted  to  the  mains  water  supply  to 

the appliance.

 

`

The  discharge  pipe  should  not  be 

blocked or used for any other purpose.

 

`

The  tundish  should  not  be  located 

adjacent to electrical components.

4. Commissioning & Controls

4.1 Commissioning procedure

 

`

Ensure water supply is turned on - allow tank to fill.

 

`

Switch on electrical supply to the water heater. You 

will notice that the display and all options will light 

up for a few seconds.

 

`

After  a  few  seconds  the  display  will  go  into  its 

default "S" smart setting. The "°C" graphic will blink 

indicating water heating cycle is active.

 

`

In this default mode the temperature of the water is 

automatically selected but will adjust based on the 
usage patterns learnt.

4.2 User Interface

WARNING

DO NOT apply electicial power to the water 

heater  until  the  unit  has  been  filled  with 

water.

S

Figure 5: User interface

Item

Description

1

Mode selection and programming

2

Selected mode 

3

Temp up/level up

4

Temp down/level down

5

2 digit display

6

Program periods

7

Validation and Boost

Table 3: User interface