3.4 INSTALLATION - ELECTRICAL REQUIREMENTS
WARNING: THIS APPLIANCE MUST BE EARTHED. IT IS SUITABLE FOR A.C.
SUPPLY ONLY. DISCONNECT THE ELECTRICAL SUPPLY BEFORE REMOVING
THE TERMINAL COVER. INSTALLATION MUST BE IN ACCORDANCE WITH
THE CURRENT IEE WIRING REGULATIONS.
1. The unit is supplied fitted with a 1.0m 3 core 1.5mm
2
flexible cable. The
electicity supply should be fused 13 Amp for a 3kW model and be via a
double pole isolating switch with a contact separation of at least 3mm in
both poles. Refer to the schematic wiring diagram below.
2. The wires are colour coded as follows:
Green and Yellow EARTH
Brown
LIVE
(L)
Blue
NEUTRAL
(N)